4. Assign a GPI trigger type to the selected GPI output as follows:
•
Press
1. Type
.
•
Use the
UP ARROW
or
DOWN ARROW
(
1
or
10
) buttons to select a trigger
type. You can choose between the following:
~
Edge
— Use this option to have the GPI output held at the selected state (low
or high) until triggered, whereupon the line switches to the opposite state
momentarily – and returns to the original state.
~
Level
— Use this option to have the GPI output port is held at the selected
state (low or high) until triggered, whereupon the line switches to the opposite
state – and holds in that state.
•
Press the right
SEL
button to accept the new settings.
5. Assign a polarity for the selected GPI output as follows:
•
Press
2. Polarity
.
•
Use the
UP ARROW
or
DOWN ARROW
(
1
or
10
) buttons to select a polarity
type.You can choose between the following:
~
Low
— Use this option when the outgoing GPI line is normally high. When
triggered, the selected line goes low (to ground).
~
High
— Use this option when the outgoing GPI line is normally low. When
triggered, the selected line goes high (released from ground).
•
Press the right
SEL
button to accept the new settings.
6. Associate a BNC with the selected GPI as follows:
•
Press
3. BNC
.
•
Use the
UP ARROW
or
DOWN ARROW
(
1
or
10
) buttons to select a BNC with
a GPI. When that BNC goes on-air the GPI associated with it is triggered. You can
choose a BNC number between
1
and
16
.
•
Press the right
SEL
button to accept the new settings.
7. Press
MENU
to display the
Installation Change Screen
.
8. Accept or cancel these changes as follows:
•
Press
0. Confirm
to accept the changes.
•
Press
1. Cancel
to exit the menus safely, without making any changes. The system
returns to the previously stored settings.
This completes the procedure to configure a GPI Output.
Содержание Synergy 100
Страница 1: ...Ross Video Limited Installation Guide Software Issue 16 10 S100...
Страница 10: ......
Страница 16: ...vi Contents Synergy 100 Installation Guide v16 10 S100...
Страница 66: ...2 32 Installation Synergy 100 Installation Guide v16 10 S100...
Страница 88: ...5 6 Using the Menu System Synergy 100 Installation Guide v16 10 S100...
Страница 100: ...6 12 BNC Configuration and Check Synergy 100 Installation Guide v16 10 S100...
Страница 134: ...7 34 Communication Setup Synergy 100 Installation Guide v16 10 S100...
Страница 170: ...8 36 Additional Installation Setups Synergy 100 Installation Guide v16 10 S100...
Страница 186: ...9 16 Completing Setup Synergy 100 Installation Guide v16 10 S100...
Страница 208: ...10 22 Appendix A Specifications Synergy 100 Installation Guide v16 10 S100...
Страница 216: ...11 8 Appendix B Hardware Options Synergy 100 Installation Guide v16 10 S100...
Страница 234: ...GL 4 Glossary of Terms Synergy 100 Installation Guide v16 10 S100...
Страница 246: ...IX 12 Index Synergy 100 Installation Guide v16 10 S100...