
8–30 • Additional Installation Setups
Synergy 100 Installation Guide (v16.10-S100)
Remote Aux Panel GPI Connection
In this section, you will wire each Remote Aux Panel GPI port to the designated joystick switch on
selected camera CCUs. If you wish to connect GPIs on
more than one
panel to different CCU
joysticks, each connector must be wired at this time. The GPI connector is located on the rear of each
“new generation” Remote Aux Panel.
•
Using the “
Remote Aux Panel GPI Input Worksheet
” as a guide, label the rear of each
panel with its assigned
group
and
offset
. A sample label is shown below.
Remote Aux Panel GPI Port – A Sample Label
•
Using the the section “
” on page 10-17 and the data from
your “
Remote Input Worksheet
” wire the appropriate GPI ports to each designated
Camera CCU. Refer to your camera’s
Installation Manual
for pinout information on the
device’s Joystick contact closure. Momentary action, normally-open switches are
recommended.
Please note:
•
Remote Aux Panel GPI Connector type: 9-pin “D” SUB Female
•
GPI In 1-8: Active low, short-to-ground to activate
•
Run all GPI cables in accordance with good engineering practice and ensure that the
cable will not be subjected to physical abuse.
Setting Up CCU Joystick Aux Control
Once the remote GPIs have been wired, and the remote panels have been programmed with the
appropriate offsets, you can now assign each remote GPI to an Aux Bus and a switcher BNC input.
This procedure selects the crosspoints that you want to view when CCU Joystick buttons are pressed.
Use the following procedure to configure your remote Aux GPIs:
1. Navigate to the
GPIs Menu
as follows:
•
Press
MENU
to display the
Main Menu
.
•
Press
3. GPIs
to display the
GPIs Menu
.
Caution
GPI inputs are only intended for connection to “dry contact,” open
collector type transistor outputs or 5 VDC signals. Application of any
negative voltages or voltages in excess of 5 VDC may permanently
damage the GPI inputs.
J5
MAIN
J1
ECHO
J4
POWER
J2
GPI
+5 V REG
1 A
GROUP 1 / OFFSET 0
Содержание Synergy 100
Страница 1: ...Ross Video Limited Installation Guide Software Issue 16 10 S100...
Страница 10: ......
Страница 16: ...vi Contents Synergy 100 Installation Guide v16 10 S100...
Страница 66: ...2 32 Installation Synergy 100 Installation Guide v16 10 S100...
Страница 88: ...5 6 Using the Menu System Synergy 100 Installation Guide v16 10 S100...
Страница 100: ...6 12 BNC Configuration and Check Synergy 100 Installation Guide v16 10 S100...
Страница 134: ...7 34 Communication Setup Synergy 100 Installation Guide v16 10 S100...
Страница 170: ...8 36 Additional Installation Setups Synergy 100 Installation Guide v16 10 S100...
Страница 186: ...9 16 Completing Setup Synergy 100 Installation Guide v16 10 S100...
Страница 208: ...10 22 Appendix A Specifications Synergy 100 Installation Guide v16 10 S100...
Страница 216: ...11 8 Appendix B Hardware Options Synergy 100 Installation Guide v16 10 S100...
Страница 234: ...GL 4 Glossary of Terms Synergy 100 Installation Guide v16 10 S100...
Страница 246: ...IX 12 Index Synergy 100 Installation Guide v16 10 S100...