Synergy 100 Installation Guide (v16.10-S100)
Additional Installation Setups • 8–25
5. If you selected
MemRecall
in the
Function
option, you must select a memory to be
recalled when a GPI input pulse is received as follows:
•
Press
2. Memory
.
•
Use the
UP ARROW
or
DOWN ARROW
(
1
or
10
) buttons to select the memory
to be recalled when a GPI input pulse is received.
•
Press the right
SEL
button to accept the new settings.
6. If you selected any option other than the
MemRecall
in the
Function
heading, the
Area
heading is displayed. You must now select an area on the switcher panel the input
GPI will trigger as follows:
•
Press
2. Area
.
•
Use the
UP ARROW
or
DOWN ARROW
(
1
or
10
) buttons to select the button or
transition the incoming GPI will trigger. You can choose between the following:
~
MLE
— Use this option when you want the incoming GPI to trigger either a
Cut
or an
AutoTrans
in the
Transition Control
area.
~
FTB
— Use this option when you want the incoming GPI to trigger the
Fade
to Black
button.
~
DSK
— Use this option when you want the incoming GPI to trigger either a
DSK Cut
or a
DSK Dissolve
in the
Transition Control
area.
•
Press the right
SEL
button to accept the new settings.
7. Set the polarity for the select port of the incoming GPI trigger as follows:
•
Press
3. Polarity
.
•
Use the
UP ARROW
or
DOWN ARROW
(
1
or
10
) buttons to select a polarity for
the incoming GPI trigger. You can choose between the following:
~
Low
— Use this option to have the selected port trigger when the line goes low
(to ground). The incoming GPI line is normally high.
~
High
— Use this option to have the selected port trigger when the line goes
high (released from ground). The incoming GPI line is normally low.
If you are assigning the polarity of a GPI input that will trigger a DSK transition, refer to
the following table for reference.
•
Press
SEL
the right
SEL
button to accept the new settings.
8. Set the type of trigger for incoming GPIs as follows:
•
Press
4. Type
.
•
Use the
UP ARROW
or
DOWN ARROW
(
1
or
10
) buttons to select the type of
trigger for the selected incoming GPI. Refer to your source device’s
Installation
Manual
for details on the specific type of GPI pulse that each device provides.You
can choose between the following:
GPI Polarity - for DSK Transitions
GPI Polarity
Signal
Key
Low
Low
On Air
Low
High
Off Air
High
Low
Off Air
High
High
On Air
Содержание Synergy 100
Страница 1: ...Ross Video Limited Installation Guide Software Issue 16 10 S100...
Страница 10: ......
Страница 16: ...vi Contents Synergy 100 Installation Guide v16 10 S100...
Страница 66: ...2 32 Installation Synergy 100 Installation Guide v16 10 S100...
Страница 88: ...5 6 Using the Menu System Synergy 100 Installation Guide v16 10 S100...
Страница 100: ...6 12 BNC Configuration and Check Synergy 100 Installation Guide v16 10 S100...
Страница 134: ...7 34 Communication Setup Synergy 100 Installation Guide v16 10 S100...
Страница 170: ...8 36 Additional Installation Setups Synergy 100 Installation Guide v16 10 S100...
Страница 186: ...9 16 Completing Setup Synergy 100 Installation Guide v16 10 S100...