5 - 118
Chapter 5 Data Used for Positioning Control
Storage item
Storage details
Reading the monitor value
Starting history (U
p to 16 rec
ords can be
stored)
Md.54
Start
Year: month
The starting time (Year: month) is
stored.
Refresh cycle: At start
Monitoring is carried out with a hexadecimal display.
0
b15
b12
0 0 0 1 0 0 0 0 0 0
0 1 1 0
b8
b4
b0
8
0
6
0
Buffer memory (stored with BCD code)
0 to 9
0 to 9
0 to 1
01 to 12 (month)
0 to 9
Monitor value
8
0
0
6
00 to 99 (year)
0
Md.5
Start
Day: hour
The starting time (Day: hour) is
stored.
Refresh cycle: At start
Monitoring is carried out with a hexadecimal display.
0
b15
b12
0 1 0 1 0 0 0 0 0 0 1 0 1 0 1
b8
b4
b0
8
1
5
2
Buffer memory (stored with BCD code)
0 to 3
0 to 9
0 to 2
00 to 23 (hour)
0 to 9
Monitor value
8
2
1
5
01 to 31 (day)
Md.6
Start
Minute:
second
The starting time (Minute:
second) is stored.
Refresh cycle: At start
Monitoring is carried out with a hexadecimal display.
0 to 5
00 to 59 (second)
0
b15
b12
1 0 0 1 0 0 1 0 0 0 0 0 1 1 1
b8
b4
b0
9
0
7
4
Buffer memory (stored with BCD code)
0 to 5
0 to 9
00 to 59 (minute)
0 to 9
Monitor value
9
4
0
7
Md.7
Error
judgment
[Storage details]
This area stores the following results of the error judgment performed
upon starting:
Warning flag
BUSY start
Control mode switching during BUSY
Control mode switching during zero speed OFF
Outside control mode range
Control mode switching
Error flag
Error code
Refresh cycle: At start
[Reading the monitor value]
Monitoring is carried out with a hexadecimal display.
b15
b12
b8
b4
b0
A
B
C
D
B
a
C
D
Buffer memory
Monitor value
D
C
B
A
Error flag OFF
Stored contents
Storage value
0
1
Error flag ON
Error flag
Error code
Convert the hexadecimal value "a, B, C, D" into a decimal value and
match it with Section "16.5 List of errors".
Warning flag
Warning OFF
Stored contents
Storage value
0
1
Warning ON
Md.8
Start history
pointer
Indicates a pointer No. that is
next to the pointer No. assigned
to the latest of the existing
starting history records.
Refresh cycle: At start
Monitoring is carried out with a decimal display.
Monitor value
Storage value (Pointer number)
0 to 15
Note: If a start signal is issued against an operating axis, a record relating to this event may be output before a record
relating to an earlier start signal is output.
Содержание MELSEC-L Series
Страница 1: ...MELSEC L LD77MS Simple Motion Module User s Manual Positioning Control LD77MS2 LD77MS4 LD77MS16 ...
Страница 2: ......
Страница 30: ...MEMO ...
Страница 70: ...2 10 Chapter 2 System Configuration MEMO ...
Страница 83: ...3 13 Chapter 3 Specifications and Functions MEMO ...
Страница 103: ...3 33 Chapter 3 Specifications and Functions MEMO ...
Страница 107: ...3 37 Chapter 3 Specifications and Functions MEMO ...
Страница 111: ...3 41 Chapter 3 Specifications and Functions MEMO ...
Страница 115: ...3 45 Chapter 3 Specifications and Functions MEMO ...
Страница 140: ...4 22 Chapter 4 Installation Wiring and Maintenance of the Product MEMO ...
Страница 253: ...5 113 Chapter 5 Data Used for Positioning Control MEMO ...
Страница 342: ...5 202 Chapter 5 Data Used for Positioning Control MEMO ...
Страница 438: ...7 20 Chapter 7 Memory Configuration and Data Process MEMO ...
Страница 440: ...MEMO ...
Страница 485: ...9 25 Chapter 9 Major Positioning Control MEMO ...
Страница 594: ...9 134 Chapter 9 Major Positioning Control MEMO ...
Страница 624: ...10 30 Chapter 10 High Level Positioning Control MEMO ...
Страница 656: ...11 32 Chapter 11 Manual Control MEMO ...
Страница 690: ...12 34 Chapter 12 Expansion Control MEMO ...
Страница 798: ...13 108 Chapter 13 Control Sub Functions MEMO ...
Страница 866: ...14 68 Chapter 14 Common Functions MEMO ...
Страница 884: ...15 18 Chapter 15 Dedicated Instructions MEMO ...
Страница 899: ...16 15 Chapter 16 Troubleshooting MEMO ...
Страница 1036: ...Appendix 88 Appendices MEMO ...
Страница 1039: ......