Appendix - 80
Appendices
Item
IAI electric actuator controller
MR-J4(W)-B
Amplifier-less operation function
Not possible
(Note-1)
Possible
(Operates artificially as the followings during
amplifier-less operation.
Servo amplifier type: MR-J4-10B, Motor type: HG-
KR053 (resolution per servomotor rotation: 4194304
pulses/rev))
Servo parameter change request
Not possible
Possible (1 word write)
Driver communication
Not possible
Possible
Monitoring of servo parameter
error No.
Not possible
Possible
Servo alarm/warning
(Error history/warning history)
Alarm codes/warning codes detected by IAI
electric actuator controller and operation
error codes during driver OPR method are
stored in "Servo alarm/warning".
Alarm codes/warning codes detected by servo
amplifier are stored in "Servo alarm/warning".
Md.108
Servo status
High-order buffer memory address
b0: READY ON
b1: Servo ON
b7: Servo alarm
b12: In-position
b13: Torque limit
High-order buffer memory address
b0: READY ON
b1: Servo ON
b2, b3: Control mode
b4: Gain switching
b5: Fully closed loop control
b7: Servo alarm
b12: In-position
b13: Torque limit
b14: Absolute position lost
b15: Servo warning
Low-order buffer memory address
b0: Zero point pass
b3: Zero speed
b4: Speed limit
b8: PID control
Md.500
Servo status7
b9: Driver operation alarm
―
Programming tool
MR Configurator2 is not available.
Use IAI electric actuator controller editing
software.
MR Configurator2 is available.
(Note-1): Set as the unconnected status during amplifier-less operation.
[3] Precautions during control
(1) Absolute position system (ABS)
The INC motor is built-in the IAI electric actuator controlled by the IAI
electric actuator controller. The IAI electric actuator controller is not
compatible with the absolute position system.
Содержание MELSEC-L Series
Страница 1: ...MELSEC L LD77MS Simple Motion Module User s Manual Positioning Control LD77MS2 LD77MS4 LD77MS16 ...
Страница 2: ......
Страница 30: ...MEMO ...
Страница 70: ...2 10 Chapter 2 System Configuration MEMO ...
Страница 83: ...3 13 Chapter 3 Specifications and Functions MEMO ...
Страница 103: ...3 33 Chapter 3 Specifications and Functions MEMO ...
Страница 107: ...3 37 Chapter 3 Specifications and Functions MEMO ...
Страница 111: ...3 41 Chapter 3 Specifications and Functions MEMO ...
Страница 115: ...3 45 Chapter 3 Specifications and Functions MEMO ...
Страница 140: ...4 22 Chapter 4 Installation Wiring and Maintenance of the Product MEMO ...
Страница 253: ...5 113 Chapter 5 Data Used for Positioning Control MEMO ...
Страница 342: ...5 202 Chapter 5 Data Used for Positioning Control MEMO ...
Страница 438: ...7 20 Chapter 7 Memory Configuration and Data Process MEMO ...
Страница 440: ...MEMO ...
Страница 485: ...9 25 Chapter 9 Major Positioning Control MEMO ...
Страница 594: ...9 134 Chapter 9 Major Positioning Control MEMO ...
Страница 624: ...10 30 Chapter 10 High Level Positioning Control MEMO ...
Страница 656: ...11 32 Chapter 11 Manual Control MEMO ...
Страница 690: ...12 34 Chapter 12 Expansion Control MEMO ...
Страница 798: ...13 108 Chapter 13 Control Sub Functions MEMO ...
Страница 866: ...14 68 Chapter 14 Common Functions MEMO ...
Страница 884: ...15 18 Chapter 15 Dedicated Instructions MEMO ...
Страница 899: ...16 15 Chapter 16 Troubleshooting MEMO ...
Страница 1036: ...Appendix 88 Appendices MEMO ...
Страница 1039: ......