Position-speed switching signal setting
(1) The following table shows the items that must be set to use the external
command signals [DI] as position-speed switching signals.
Setting item
Setting
value
Setting details
Buffer memory address
LD77MS2
LD77MS4
LD77MS16
Pr.42
External
command
function selection
2
Speed-position, position-speed
switching request.
62+150n
Cd.8
External
command valid
1
Validates an external
command.
1505+100n 4305+100n
Cd.45
Speed-position
switching device
selection
0
Use the external command
signal for switching from
position control to speed
control.
1566+100n 4366+100n
(Note): Set the external command signal [DI] in "
Pr.95
External command signal selection
" at LD77MS16 use.
Refer to Section 5.2 "List of parameters" and Section 5.7 "List of control data" for information on the
setting details.
(2) The following table shows the items that must be set to use the near-point dog
signal (DOG) as position-speed switching signals.
Setting item
Setting
value
Setting details
Buffer memory address
LD77MS2
LD77MS4
LD77MS16
Cd.45
Speed-position
switching device
selection
1
Use the near-point dog signal
for switching from position
control to speed control.
1566+100n 4366+100n
(Note): The setting is not required for "
Pr.42
External command function selection
" and "
Cd.8
External command
valid
".
Refer to Section 5.7 "List of control data" for information on the setting details.
(3) The following table shows the items that must be set to use "
Cd.46
Speed-
position switching command
" as position-speed switching signals.
Setting item
Setting
value
Setting details
Buffer memory address
LD77MS2
LD77MS4
LD77MS16
Cd.45
Speed-position
switching device
selection
2
Use the "
Cd.46
Speed-position
switching command
" for
switching from position control
to speed control.
1566+100n 4366+100n
(Note): The setting is not required for "
Pr.42
External command function selection
" and "
Cd.8
External command
valid
".
Refer to Section 5.7 "List of control data" for information on the setting details.
Содержание MELSEC-L Series
Страница 1: ...MELSEC L LD77MS Simple Motion Module User s Manual Positioning Control LD77MS2 LD77MS4 LD77MS16 ...
Страница 2: ......
Страница 30: ...MEMO ...
Страница 70: ...2 10 Chapter 2 System Configuration MEMO ...
Страница 83: ...3 13 Chapter 3 Specifications and Functions MEMO ...
Страница 103: ...3 33 Chapter 3 Specifications and Functions MEMO ...
Страница 107: ...3 37 Chapter 3 Specifications and Functions MEMO ...
Страница 111: ...3 41 Chapter 3 Specifications and Functions MEMO ...
Страница 115: ...3 45 Chapter 3 Specifications and Functions MEMO ...
Страница 140: ...4 22 Chapter 4 Installation Wiring and Maintenance of the Product MEMO ...
Страница 253: ...5 113 Chapter 5 Data Used for Positioning Control MEMO ...
Страница 342: ...5 202 Chapter 5 Data Used for Positioning Control MEMO ...
Страница 438: ...7 20 Chapter 7 Memory Configuration and Data Process MEMO ...
Страница 440: ...MEMO ...
Страница 485: ...9 25 Chapter 9 Major Positioning Control MEMO ...
Страница 594: ...9 134 Chapter 9 Major Positioning Control MEMO ...
Страница 624: ...10 30 Chapter 10 High Level Positioning Control MEMO ...
Страница 656: ...11 32 Chapter 11 Manual Control MEMO ...
Страница 690: ...12 34 Chapter 12 Expansion Control MEMO ...
Страница 798: ...13 108 Chapter 13 Control Sub Functions MEMO ...
Страница 866: ...14 68 Chapter 14 Common Functions MEMO ...
Страница 884: ...15 18 Chapter 15 Dedicated Instructions MEMO ...
Страница 899: ...16 15 Chapter 16 Troubleshooting MEMO ...
Страница 1036: ...Appendix 88 Appendices MEMO ...
Страница 1039: ......