9 - 33
Chapter 9 Major Positioning Control
Restrictions
An error will occur and the positioning will not start in the following cases. The
machine will immediately stop if the error is detected during a positioning control.
If the movement amount of each axis exceeds "1073741824 (=2
30
)" when "0:
Composite speed" is set in "
Pr.20
Interpolation speed designation method
"
The error "Outside linear movement amount range" (error code: 504) occurs at a
positioning start.
(The maximum movement amount that can be set in "
Da.6
Positioning address/
movement amount
" is "1073741824 (=2
30
)".)
Positioning data setting example
[When "2-axis linear interpolation control (ABS linear 2)" is set in positioning data
No. 1 of axis 1]
• Reference axis ............. Axis 1
• Interpolation axis.......... Axis 2 (The required values are also set in positioning
data No. 1 of axis 2.)
Axis
Setting item
LD77MS2/LD77MS4
setting example
LD77MS16
setting example
Setting details
Axis 1
(reference
axis)
Axis 2
(interpolation
axis)
Axis 1
(reference
axis)
Axis 2
(interpolation
axis)
A
xi
s 1
P
os
iti
oni
ng dat
a No.
1
Da.1
Operation pattern
Positioning
complete
–
Positioning
complete
–
Set "Positioning complete" assuming the next
positioning data will not be executed.
Da.2
Control method
ABS
linear 2
–
ABS
linear 2
–
Set absolute system 2-axis linear interpolation
control.
Da.3
Acceleration time No.
1
–
1
–
Designate the value set in "
Pr.25
Acceleration
time 1
" as the acceleration time at start.
Da.4
Deceleration time No.
0
–
0
–
Designate the value set in "
Pr.10
Deceleration
time 0
" as the deceleration time at deceleration.
Da.5
Axis to be interpolated
LD77MS2
LD77MS4
Axis 2
–
Set the axis to be interpolated (partner axis).
If the self-axis is set, an error will occur.
Da.6
Positioning address/
movement amount
10000.0
m
4000.0
m
10000.0
m
4000.0
m
Set the end point address. (Assuming "mm" is
set in "
Pr.1
Unit setting
".)
Da.7
Arc address
–
–
–
–
Setting not required (setting value is ignored).
Da.8
Command speed
6000.00
mm/min
–
6000.00
mm/min
–
Set the speed during movement to the end
point address.
Da.9
Dwell time/JUMP
destination positioning
data No.
500ms – 500ms –
Set the time the machine dwells after the
positioning stop (command stop) to the output
of the positioning complete signal.
Da.10
M code/Condition
data No./Number of
LOOP to LEND
repetitions
10 – 10 –
Set this when other sub operation commands
are issued in combination with the No.1
positioning data.
Da.20
Axis to be interpolated
No.1
LD77MS16
Axis
2
–
Set the axis to be interpolated.
If the self-axis is set, an error will occur.
Da.21
Axis to be interpolated
No.2
LD77MS16
–
–
Setting not required (setting value is ignored).
Da.22
Axis to be interpolated
No.3
LD77MS16
–
–
(Note): Refer to Section 5.3 "List of positioning data" for information on the setting details.
Содержание MELSEC-L Series
Страница 1: ...MELSEC L LD77MS Simple Motion Module User s Manual Positioning Control LD77MS2 LD77MS4 LD77MS16 ...
Страница 2: ......
Страница 30: ...MEMO ...
Страница 70: ...2 10 Chapter 2 System Configuration MEMO ...
Страница 83: ...3 13 Chapter 3 Specifications and Functions MEMO ...
Страница 103: ...3 33 Chapter 3 Specifications and Functions MEMO ...
Страница 107: ...3 37 Chapter 3 Specifications and Functions MEMO ...
Страница 111: ...3 41 Chapter 3 Specifications and Functions MEMO ...
Страница 115: ...3 45 Chapter 3 Specifications and Functions MEMO ...
Страница 140: ...4 22 Chapter 4 Installation Wiring and Maintenance of the Product MEMO ...
Страница 253: ...5 113 Chapter 5 Data Used for Positioning Control MEMO ...
Страница 342: ...5 202 Chapter 5 Data Used for Positioning Control MEMO ...
Страница 438: ...7 20 Chapter 7 Memory Configuration and Data Process MEMO ...
Страница 440: ...MEMO ...
Страница 485: ...9 25 Chapter 9 Major Positioning Control MEMO ...
Страница 594: ...9 134 Chapter 9 Major Positioning Control MEMO ...
Страница 624: ...10 30 Chapter 10 High Level Positioning Control MEMO ...
Страница 656: ...11 32 Chapter 11 Manual Control MEMO ...
Страница 690: ...12 34 Chapter 12 Expansion Control MEMO ...
Страница 798: ...13 108 Chapter 13 Control Sub Functions MEMO ...
Страница 866: ...14 68 Chapter 14 Common Functions MEMO ...
Страница 884: ...15 18 Chapter 15 Dedicated Instructions MEMO ...
Страница 899: ...16 15 Chapter 16 Troubleshooting MEMO ...
Страница 1036: ...Appendix 88 Appendices MEMO ...
Страница 1039: ......