10 - 7
Chapter 10 High-Level Positioning Control
10.3 Setting the block start data
10.3.1 Relation between various controls and block start data
The "block start data" must be set to carry out "high-level positioning control". The
setting requirements and details of each "block start data" item to be set differ
according to the "
Da.13
Special start instruction" setting.
The following shows the "block start data" setting items corresponding to various
control methods. The operation details of each control type are explained starting in
Section 10.3.2. Also refer to Section 10.4 "Setting the condition data" for details on
"condition data" with which control execution is judged.
(The "block start data" settings in this chapter are assumed to be carried out using
GX Works2.)
High-level positioning
control
Block start data
setting items
Block start
(Normal
start)
Condition
start
Wait start
Simulta-
neous start
Repeated
start
(FOR loop)
Repeated
start
(FOR
condition)
NEXT start
Da.11 Shape
0 : End
1 : Continue
Da.12 Start data No.
1 to 600
Da.13
Special start
instruction
0 1 2 3 4 5 6
Da.14 Parameter
–
Condition data No.
Number of
repetitions
Condition
data No.
–
: One of the two setting items must be set.
: Set as required (Set to "–" when not used.)
: Setting not possible
–
: Setting not required (Set the initial value or a value within the setting range.)
The "NEXT start" instruction is used in combination with "repeated start (FOR loop)" and "repeated start (FOR
condition)". Control using only the "NEXT start" will not be carried out.
REMARK
It is recommended that the "block start data" be set whenever possible with
GX Works2. Execution by sequence program uses many sequence programs and
devices. The execution becomes complicated, and the scan times will increase.
Содержание MELSEC-L Series
Страница 1: ...MELSEC L LD77MS Simple Motion Module User s Manual Positioning Control LD77MS2 LD77MS4 LD77MS16 ...
Страница 2: ......
Страница 30: ...MEMO ...
Страница 70: ...2 10 Chapter 2 System Configuration MEMO ...
Страница 83: ...3 13 Chapter 3 Specifications and Functions MEMO ...
Страница 103: ...3 33 Chapter 3 Specifications and Functions MEMO ...
Страница 107: ...3 37 Chapter 3 Specifications and Functions MEMO ...
Страница 111: ...3 41 Chapter 3 Specifications and Functions MEMO ...
Страница 115: ...3 45 Chapter 3 Specifications and Functions MEMO ...
Страница 140: ...4 22 Chapter 4 Installation Wiring and Maintenance of the Product MEMO ...
Страница 253: ...5 113 Chapter 5 Data Used for Positioning Control MEMO ...
Страница 342: ...5 202 Chapter 5 Data Used for Positioning Control MEMO ...
Страница 438: ...7 20 Chapter 7 Memory Configuration and Data Process MEMO ...
Страница 440: ...MEMO ...
Страница 485: ...9 25 Chapter 9 Major Positioning Control MEMO ...
Страница 594: ...9 134 Chapter 9 Major Positioning Control MEMO ...
Страница 624: ...10 30 Chapter 10 High Level Positioning Control MEMO ...
Страница 656: ...11 32 Chapter 11 Manual Control MEMO ...
Страница 690: ...12 34 Chapter 12 Expansion Control MEMO ...
Страница 798: ...13 108 Chapter 13 Control Sub Functions MEMO ...
Страница 866: ...14 68 Chapter 14 Common Functions MEMO ...
Страница 884: ...15 18 Chapter 15 Dedicated Instructions MEMO ...
Страница 899: ...16 15 Chapter 16 Troubleshooting MEMO ...
Страница 1036: ...Appendix 88 Appendices MEMO ...
Страница 1039: ......