E N T 4 1 3 0
Model Name:
RJ–4100
E N T 4 1 3 0
Model Name:
RJ–4100
Trouble with Printing
When No Error is Displayed on the Printer's Liquid Crystal Display
1
• Bad right angle precision
1-1
1-2
1-3
1-4
• Is the media that is mounted a type that is recommended by Mutoh?
→
No guarantee can be given if the media is not media recommended by Mutoh. Please confirm after replacing
with media recommended by Mutoh.
• Does the media that is mounted have a peculiar tendency to bend?
→
Either curb this tendency or replace it with new media and try again.
• Is the media mounted properly in the main unit? Is there any "skew" or "meander"?
→
Skew and meander are caused by wrongly mounted media and this is probably affecting accuracy. Please
confirm after remounting the media properly.
• Are paper scraps or foreign matter adhering to the pressure roller and grid roller?
→
Wipe the pressure roller with a soft damp cloth. (Refer to CON5010)
→
Clean the grid roller with a nylon brush. (Refer to CON5010)
❈
If the above procedures do not improve the symptoms, the main unit has probably developed a fault for
some reason.
Go to MAP4000
No.
Symptom
Sequence
Items to be Confirmed
When No Error is Displayed on the Printer's Liquid Crystal Display
Trouble with Printing
83