Trouble with Printing
When No Error is Displayed on the Printer's Liquid Crystal Display
1
• Inaccurate line distance in the direc-
tion of media feed
(Subsidiary scanning distance)
1-1
1-2
1-3
1-4
1-5
1-6
1-7
• Are environmental conditions within the range recommended for assured operation as
checked in the primary consultation?
→
After checking compliance with the range recommended for assured operation, please
explain these points in detail.
• Has distance been compensated using the existing media as checked in the primary con-
sultation?
→
Carry out distance compensation.
→
Even if the distance has been compensated using the existing media, do it for verifica-
tion.
• Is the X drive pulley set screw loose?
→
Re-tighten the screw.
• Is the X speed reduction pulley set screw loose?
→
Tighten it securely.
• Is the X speed reduction belt tension adjusted to the prescribed value (4.2 kg ± 0.2 kg)
→
Readjust it.
• Are all the pressure rollers (15) pressurizing the media?
• With the pressure lever raised, do any pressure rollers seem reluctant to turn?
• With the pressure lever lowered, are any of the pressure rollers idling or [kata atari ?]
• With the pressure lever lowered, is the plate pressing strongly on the media?
→
If there is paper dust or scraps near the pressure rollers, wipe with a soft damp cloth.
(Refer to CON5010)
→
If necessary, replace pressure assembly, pressure rollers and plate.
→
If the gap between platen and plate is less than 0.2 mm, adjust platen height.
• Is the rough surface of the grid roller worn in some places?
• Is the grid roller heavy to turn? Or does it not turn smoothly?
→
If there is paper dust or scraps sticking to the grid roller, clean it with a nylon brush.
(Refer to CON5010)
→
If necessary, replace the grid roller assembly and coupling assembly.
No.
Symptom
Sequence
Items to be Confirmed
When No Error is Displayed on the Printer's Liquid Crystal Display
Trouble with Printing
1670
1670
1560
1220
1520
1210
2120
R E P
B A C
G O T O R e f . P a g e s
177
Direction of media feed
Standard Value
500 mm ±0.1%
Since the adjustment here is 300 mm,
the measured value, x is such that
299.7 mm
≤
x
≥
300.3 mm