Y Motor Assembly
Screws
Screw
R E P 1 2 8 0
Model Name:
RJ–4100
R E P 1 2 8 0
Model Name:
RJ–4100
How to replace the Y Motor Assembly
How to replace the Y Motor Assembly
GO TO
TEST NO
1001
TEST4
Item
Replacement and Adjustment Procedure
1. Replacement
Procedure
2. Adjustment
and
Examination
Procedure
238
Replace the Y Motor Assembly
1. Remove the Left and Right Covers.
(Refer to REP1010)
2. Remove the Rear Paper Guide.
(Refer to REP1040)
3. Remove the Steel Belt.
(Refer to REP1290)
4. Open the Control Box.
(Refer to REP1050)
5. Disconnect connector J119 (YMOT) from the Main Board
Assembly.
6. Remove the Y Motor Assembly. (3 fastening screws)
7. Assembling is the reverse of the removal procedure.
Reference: Since the Y Motor Assembly Cable passes below
the Cartridge Unit, the work will be easier if you
remove the two Cartridge Base screws and push
it back.
1. Carry out the Steel Belt Tensioning Adjustment. (Refer to
REP1550)