E X A 4 0 1 0
Model Name:
RJ–4100
E X A 4 0 1 0
Model Name:
RJ–4100
Trouble with Printing
When No Error is Displayed on the Printer's Liquid Crystal Display
1
• There is an extra feed after printing is
finished
1-1
1-2
1-3
1-4
1-5
• Are paper sensors XF/XR working normally according to the diagnostic sensor test?
→
Check the connections of paper sensor F and paper sensor R connectors.
Paper sensor F is the main board connector J101 (XF) and paper sensor R is J108
(XR).
→
Replace paper sensors F and R.
• Is there a problem with the printer driver software?
→
Upgrade the printer driver version.
• Is there a problem with the remote panel utility (RPU)?
→
Upgrade the RPU version.
• Is there a problem with the program ROM?
→
Upgrade the version.
• The main board assembly may be damaged.
→
Replace it.
No.
Symptom
Sequence
Items to be Confirmed
When No Error is Displayed on the Printer's Liquid Crystal Display
Trouble with Printing
1190
1200
1140
1040
R E P
B A C
G O T O R e f . P a g e s
162