Standard base
Slide
Platen
Adjusting screw
Measuring position (rib)
Standard value : 0
Rail height jig
R E P 1 5 2 0
Model Name:
RJ–4100
R E P 1 5 2 0
Model Name:
RJ–4100
How to Adjust the Platen Height
How to Adjust the Platen Height
GO TO
TEST NO
Item
Replacement and Adjustment Procedure
1. Adjustment
and
Inspection
Procedure
268
Platen Height Adjustment
1. Adjust the rail height jig. (Refer to REP1610)
Mount the rail height jig on the standard base and set the
dial gauge to “0”.
Mount the rail height gauge over the ribs at both ends of the
platen, loosen the platen retaining screws and adjust the
platen up and down until the dial gauge reads 2.6 to 2.7 mm.
Standard value
2.6 to 2.7 mm by dial gauge