Spring Hook
Spring
Center
Section
Tubes
Wiper
Flag
R E P 1 2 4 0
Model Name:
RJ–4100
R E P 1 2 4 0
Model Name:
RJ–4100
How to replace the Cap Assembly
How to replace the Cap Assembly
GO TO
TEST NO
1002
TEST7
Item
Replacement and Adjustment Procedure
1. Replacement
Procedure
234
Replace the Cap Assembly
1. Remove the Panel Cover.
(Refer to REP1030)
2. Remove the Front Cover.
(Refer to REP1020)
3. Remove the Y Rail Cover.
(Refer to REP1030)
4. Remove the Front Paper Guide.
(Refer to REP1040)
5. Remove the Panel Mounting Plate.
(Refer to REP1230- 1.
to 6.)
6. Remove the Cap Assembly Spring.
7. Disconnect the two tubes from the Cap Assembly.
8. Grasp the plug on the right side of the Cap Assembly, lift it up
and remove the right side of the Cap.
9. Grasp the center section of the Cap Assembly, lift it up and
take out the Cap.
CAUTION: Be careful not to touch the surface of the Cap
or the Cleaner Head ASP.
10. Assembling is the reverse of the removal procedure.
CAUTION: When inserting tubes on the Cap Assembly,
turn the tubes clockwise through 45 to 90
degrees. (Refer to the diagram on the right)
If this is not done, you may be unable to
lower the Cap Assembly to the bottom.
CAUTION: When screwing the cap assembly to the main-
tenance frame, push it right back before fas-
tening.