Trouble with Initialization
When No Error is Displayed on the Printer's Liquid Crystal Display
1
• Can not make entries from the operat-
ing panel
1-1
1-2
1-3
1-4
1-5
• Is "Initial filling" displayed?
→
The initial filling operation takes about four minutes. Since entry from the operating panel is inhibited during
this period, please wait until initial filling is completed.
• Did "Cover open" or "Lever Up" appear when power was switched on?
→
Even with no media, unless the lever is down and the cover closed, the origin detection operation will not be
performed, the printer will not go to standby mode and all key entries will be ignored. For key operation, it
must first be initialized and go into standby mode.
• Is "Cleaning" displayed?
→
The normal and strong cleaning operations take about one minute.
Entry from the operating panel is inhibited during this period. Please wait until cleaning is finished.
• Is a CPU system error or a mechanical system error displayed?
→
If so, refer to TRB1000 and proceed to the relevant ENT page showing remedial action.
• When cut media is mounted on the printer, selecting cut media with "Shift + Media Feed" will have no effect
and even if it is entered, the operation will not be performed.
The same applies to the media cutting operation with the "CANCEL" key before data reception.
→
Change the setting to roll media.
❈
If the above procedures do not improve the symptoms, the main unit has probably developed a fault for
some reason.
Go to MAP2000