How to replace the Waste Fluid Box Detector Switch Assembly
How to replace the Waste Fluid Box Detector Switch Assembly
GO TO
TEST NO
1002
TEST9
Item
Replacement and Adjustment Procedure
1. Replacement
Procedure
218
1. Remove the Right Paper Guide.
(Refer to REP1040)
2. Open the Control Box.
(Refer to REP1050)
3. Disconnect connector J109 (TANK) from the Main Board.
4. Remove the Waste Fluid Box Detector Switch Assembly.
(2 fastening screws)
5. Assembling is the reverse of the removal procedure.
CAUTION:
Waste Fluid Box
Detector Switch
Assembly
Waste Fluid Box
Screw
Be careful not to over-tighten when mounting the Waste
Fluid Box Detector Switch Assembly.
Tightening torque is 29.4 N•cm (3 kg•cm)
Reference:
Since the Waste Fluid Box Detector Switch Assembly cable
passes below the Cartridge Unit, the work will be easier if
you remove the two Cartridge Base screws and push it back.