323
G I D 4 0 1 0
Model Name:
RJ–4100
G I D 4 0 1 0
Model Name:
RJ–4100
Power On Sequence
Power On Sequence
Power Switch ON
[Check Standard DRAM]
error occurs
[Check Optional DRAM]
error occurs
[Check NVRAM]
error occurs
[Read NVRAM]
error occurs
[Initialize Tasks]
< Enter Self-diagnostic Key >
[Cover & Lever monitoring begins]
[Encoder diagnostic check]
error occurs
[Motor excitation on]
[Origin detection]
error occurs
< Is capping position registered? >
Origin position not set
< Carriage not at capping position on startup >
Not
[Write initial values to NVRAM]
Serious Error (StdDRAM)
Serious Error (OptDRAM)
Serious Error (NVRAM)
Self-diagnostic Standby
Serious Error (Encoder)
Serious Error (Sensor)
Error Display
Strong Cleaning
Normal Standby