Mount the Kinetix 5700 Drive System
Chapter 3
Mount Your Kinetix 5700
Drive Modules
This procedure assumes that you have prepared your panel and understand
how to bond your system. For installation instructions regarding other
equipment and accessories, refer to the instructions that came with those
products.
Follow these steps to mount your Kinetix 5700 drive modules to the panel.
1.
Lay out the hole pattern for each drive module in the enclosure.
for panel layout
recommendations.
2.
Drill holes in the panel for mounting your drive system.
Refer to
beginning on
3.
Loosely attach the mounting hardware to the panel.
The recommended mounting hardware is M5 (#10-32) steel bolts.
Observe bonding techniques as described in
4.
Attach the DC-bus supply (or supplies) to the cabinet panel in the
leftmost position.
5.
Attach additional drive modules to the right of the previous module by
using the same method, but also making sure that the zero-stack tabs and
cutouts are engaged.
Zero-stack mounting is required for all configurations. See the
6.
Tighten all mounting fasteners.
Apply 4.0 N•m (35.4 lb•in) maximum torque to each fastener.
IMPORTANT
To improve the bond between the drive modules and subpanel,
construct your subpanel out of zinc plated (paint-free) steel.
2
1
Kinetix 5700 Drive System
(DC bus supply and dual-axis
inverter are shown)
Top Screws
(bottom screws not shown)
Zero-stack Tab
and Cutout Engaged