Rockwell Automation Publication 2198-UM002E-EN-P - February 2018
341
Motor Control Feature Support
Appendix D
See
for motor manufacturer performance data sheet example.
Figure 172 - Motor Manufacturer Performance Data Sheet
Motor>Model Category
From the Motor>Model category you can enter additional motor nameplate or
datasheet values (phase-to-neutral parameters) for induction motors.
The Motor>Model parameters are used in closed-loop induction-motor
control mode, sensorless vector control mode, and when FluxUp is enabled,
and are estimated automatically by the Logix Designer application based on the
motor nameplate data. You can also enter these parameter values directly from
the motor nameplate/datasheet or indirectly by running a Motor>Analyzer
test.
Figure 173 - Phase-to-Neutral Parameters
C E R T I FI C A T I ON DA T A SHE E T
T Y PI C A L M OT OR PE R FOR M A NC E DA T A
H P
kW
SY NC . R PM
F .L . R PM
F R A ME
E NC L O SUR E
K V A C O DE
DE SI G N
1
.75
1800
1725
56C
TENV
P
A
PH
H z
V O L T S
F L A MPS
ST A R T T Y PE
DUT Y
I NSL
S.F .
A MB°C
E L E V A T I O N
3
60
230/
3/
1.5
INV ER TER ONL Y
C ONTINUOUS
F 3
1.0
40
3300
F UL L L O AD E F F : 84
3/4 L O AD E F F : 82.5
1/2 L O AD E F F : 78.5
G T D. E F F
E L E C . T Y PE
NO L O A D A MPS
F UL L L O AD PF : 75
3/4 L O AD PF : 65.5
1/2 L O AD PF : 51
81.5
SQ C AGE INV DUTY
2
/
1
F .L . T O R Q UE
L O C K E D R O T O R A MPS
L .R . T O R Q UE
B.D. T O R Q UE
F .L . R I SE °C
3 L B -F T
30 / 15
10.8 L B -F T 360%
15 L B -F T 500%
65
SO UND PR E SSUR E
@ 3 F T .
SO UND PO W E R
R O T O R W K ^2
MA X . W K ^2
SA F E ST A L L T I ME
ST A R T S /
H O UR
A PPR O X .
MO T O R W G T
62 dB A
72 dB A
0.11 L B -F T ^2
0 L B -F T ^2
0 SE C .
0
42 L B S.
E QUI V A L E NT W Y E C K T .PA R A M E T E R S (OHM S PE R PHA SE )
R 1
R 2
X 1
X 2
X M
8.378
5.6232
10.7068
9.9116
278.036
R M
ZR E F
X R
T D
T D0
11132.8
284
1.7
0.0071
0.136
460
IMPORTANT
If you do not know the Stator Leakage, Rotor Leakage, Stator Resistance,
Rated Flux Current, and system inertia, you can run the static motor test and
Autotune procedure to determine the parameter values.