276
Rockwell Automation Publication 2198-UM002E-EN-P - February 2018
Chapter 9
Kinetix 5700 Safe Torque-off Function
Table 142 - Dual-axis Inverter STO Assembly Specifications
Attribute
Instance Attribute
Value
Logix Designer Tag Name
Safety input
assembly
0x1A8
Byte 0 Bit 0: Torque disabled 1
Drv:SI.TorqueDisabled1
Byte 0 Bit 6: Safety fault 1
Drv:SI.SafetyFault1
Byte 0 Bit 7: Reset required 1
Drv:SO.SafeTorqueOff1
Byte 1 Bit 0: Torque disabled 2
Drv:SI.TorqueDisabled2
Byte 1 Bit 6: Safety fault 2
Drv:SI.SafetyFault2
Byte 1 Bit 7: Reset required 2
Drv:SO.SafeTorqueOff2
Safety output
assembly
0x188
Byte 0 Bit 0: Safe torque-off output 1
Drv:SO.SafeTorqueOff1
Byte 0 Bit 7: Reset request 1
Drv:SO.Reset1
Byte 1 Bit 0: Safe torque-off output 2
Drv:SO.SafeTorqueOff2
Byte 1 Bit 7: Reset request 2
Drv:SO.Reset2