58
Rockwell Automation Publication 2198-UM002E-EN-P - February 2018
Chapter 3
Mount the Kinetix 5700 Drive System
Drill-hole Patterns by Using the System Mounting Toolkit
The mounting bar must be mounted horizontally on the system panel. The
drill-hole guide inserts behind the mounting bar and slides left and right. Holes
and slots in the drill-hole guide let you establish the location of each
Kinetix 5700 drive module.
Figure 32 - Mounting Bar
Follow these steps to locate the drill-holes by using the system mounting
toolkit.
1.
Draw a horizontal line on the panel where you would like to position the
upper module-width holes (refer to
).
2.
Drill three 3.6 mm (0.14 in.) holes 506 mm (19.9 in.) below the line you
drew in
for attaching the mounting bar to the panel.
3.
Attach the mounting bar to the panel by using the two M4 fasteners.
4.
Determine (left to right) the leftmost module position and draw a
vertical line where you would like the center of that leftmost module.
5.
Slide the drill-hole guide into the mounting bar and adjust left-to-right
until the 55 mm upper module-width hole is aligned with the vertical
line you drew in
.
6.
Mark the upper and lower module-width holes appropriate for the drive-
width of the module being mounted.
2x 190 (7.48)
2x 10 (0.39)
400 (15.75)
3x Ø4.50 (0.18)
10 (0.39)
43.2 (1.70) Ref
100
100
Mounting Bar
Drill-hole Guide
Dimensions are in mm (in.)
M4 thread-forming
fasteners, 1.7 N•m (15 lb•in)
100
100
85
85
55
Horizontal Line Drawn on Panel
Center of Leftmost Module