106
Rockwell Automation Publication 2198-UM002E-EN-P - February 2018
Chapter 5
Connect the Kinetix 5700 Drive System
Wire the Input Power Connector
The input power (IPD) connector applies to only the DC-bus power supply
and requires 324…528V AC (three-phase) for mains input power.
Figure 66 - IPD Connector Wiring - Connector Plug
Table 53 - Input Power (IPD) Connector Plug Specifications
ATTENTION:
Make sure the input power connections are correct when
wiring the IPD connector plug. Insert the plug into the module connector
and tighten screws to 0.8 N•m (7.1 lb•in). Incorrect wiring/polarity or loose
wiring can cause damage to equipment.
L3 L2 L1
L3 L2 L1
Input Power (IPD) Connector Plug
2198-P
xxx
DC-bus Power Supply
(bottom view)
Connector Screws (2)
0.8 N•m (7.1 lb•in)
DC-bus Power Supply
Cat. No.
Pin
Signal
Recommended
Wire Size
mm
2
(AWG)
Strip Length
mm (in.)
Torque Value
N•m (lb•in)
2198-P031
2198-P070
6…10
(10…8)
10.0 (0.39)
0.8 (7.1)
2198-P141
2198-P208
10…35
(8…2)
20.0 (0.79)
L3
L2
L1
L3
L2
L1