108
Rockwell Automation Publication 2198-UM002E-EN-P - February 2018
Chapter 5
Connect the Kinetix 5700 Drive System
Wiring the Digital Input
Connectors
This section provides guidelines to assist you in making digital input
connections.
Install 2198-
xxxx
-ERS3 Safety and Digital-input Connector Plugs
The right side of the safety and digital-input connector plugs require an off-
center push when inserting them into their respective connectors. This applies
to 2198-
xxxx
-ERS3 single-axis and dual-axis inverters.
Figure 68 - 2198-
xxxx
-ERS3 Safety and Digital Input Connector Plugs
IMPORTANT
An off-center push is required to engage the locking features on the
bottom of the safety and digital-input connector plugs and seat properly
with the drive (STO and IOD) connectors. Failure to do this can result in
the connector plugs pulling out of the drive connector during normal
operation.
MOD–
NET–
Digital Inputs Plug
Locking Features
Off-center Push
Push the Right-hand Side
Safety (STO) Connector Plug
Kinetix 5700 Inverter
Safety or Digital Inputs Connector Plug
(safety connector plug is shown)
Safety Plug