Rockwell Automation Publication 2198-UM002E-EN-P - February 2018
53
Mount the Kinetix 5700 Drive System
Chapter 3
Figure 25 - DC-bus Power Supply Example/Multiple Capacitor Modules (200 A, max)
Figure 26 - Regenerative Power Supply Example Power (200 A, max)
Figure 27 - Multiple DC-bus Power Supply Example/Second System (200 A, max)
2198-S
xxx
-ERS
x
2198-D
xxx
-ERS
x
2198-S
xxx
-ERS
x
2198-D
xxx
-ERS
x
2198-P
xxx
2198-
CAPMOD
-2240
2198-
CAPMOD
-2240
Capacitor
Module
Single-axis
Inverters
Dual-axis
Inverters
DC-Bus
Power Supply
DC Bus
Capacitor
Module
This example includes:
• 1 Bus group
• 1 Drive cluster
2198-S
xxx
-ERS
x
2198-D
xxx
-ERS
x
8720MC-RPS190
2198-
CAPMOD
-2240
2198-S
xxx
-ERS
x
2198-D
xxx
-ERS
x
2198-
CAPMOD
-DCBUS
-IO
Capacitor
Module
Single-axis
Inverters
Dual-axis
Inverters
DC Bus
Regenerative
Power Supply
Extension
Module
This example includes:
• 1 Bus group
• 1 Drive cluster
2198-S
xxx
-ERS
x
2198-D
xxx
-ERS
x
2198-S
xxx
-ERS
x
2198-D
xxx
-ERS
x
2198-P208
2198-
CAPMOD
-2240
2198-S
xxx
-ERS
x
2198-D
xxx
-ERS
x
2198-S
xxx
-ERS
x
2198-D
xxx
-ERS
x
2198-
CAPMOD
-2240
2198-
CAPMOD
-DCBUS
-IO
2198-
CAPMOD
-DCBUS
-IO
2198-P208
2198-P208
Capacitor
Module
Single-axis
Inverters
Dual-axis
Inverters
DC-Bus
Power Supply
Extension
Module
Extension
Module
Capacitor
Module
Single-axis
Inverters
Dual-axis
Inverters
DC Bus
DC Bus
DC-Bus
Power Supply
DC-Bus
Power Supply
This example includes:
• 1 Bus group
• 2 Drive clusters
IMPORTANT
The systems that are shown are typical. The maximum number of inverter
modules depends on the maximum system capacitance of the power
supply. When there are two or three DC-bus power supplies, they must be
catalog number 2198-P208.
Refer to Appendix C on
for more system sizing information.
IMPORTANT
The 8720MC-RPS power supply is not compatible with the iTRAK power
supply.