Rockwell Automation Publication 2198-UM002E-EN-P - February 2018
55
Mount the Kinetix 5700 Drive System
Chapter 3
Figure 29 - DC-bus Connector Example
(1) DC-bus links latch on both sides when inserted into the DC-bus connectors. To remove the DC-bus link, depress both sets of
upper pivots to unlatch the lower pivots and hold the DC-bus link firmly while pulling upward.
24V Input Power Connection System
The 24V input power connection system is optional and comprised of three
components:
• The 24V input wiring connector that plugs into the DC-bus power
supply or first module supplied by the 24V external power receives 24V
DC input wiring.
• 24V DC T-connectors that plug into the drive modules downstream
from the power supply or first module supplied by the 24V external
power where the 24V control power is shared.
• Bus bars that connect between drive modules to extend the 24V control
power from one drive module to another.
Kinetix 5700 Drive System
End Caps (2)
DC-bus Link, 85 mm
Zero-stack Tab
and Cutout Engaged
DC-bus Link, 55 mm
DC-bus Link, 100 mm
(seated)
DC-bus power supply is mounted
leftmost followed by drive with
largest amp rating.
Latch
Align the DC-bus link
lower pivots with the
latches and push downward
until they latch.
Upper Pivot
Lower Pivot
Dual Axis Inverter, 55 mm
Single Axis Inverter, 85 mm
Single Axis Inverter, 100 mm
DC-bus Power Supply
DC Link Latched
(1)
IMPORTANT
The maximum current rating for the 24V input power connection system is
52 A. If needed, you can insert another 2198-TCON-24VDCIN36 control
power input wiring connector at any point in the drive cluster.