86
Rockwell Automation Publication 2198-UM002E-EN-P - February 2018
Chapter 4
Connector Data and Feature Descriptions
EnDat Digital Feedback
Table 41 - EnDat Digital Interface Specifications
Table 42 - Support Requirements for EnDat Encoders
Auxiliary Feedback Specifications
The Kinetix 5700 inverters support multiple types of feedback devices by using
the 15-pin (UFB) connector and sharing connector pins in many cases. Refer
to
Configure Feedback-only Axis Properties
application.
Attribute
Value
EnDat Digital data communication
4 Mbps, synchronous
Requirement
EnDat Sine/Cosine
EnDat Digital
Supported models
LC 483
ECl 119
(1)
ECN 113
ECN 1313/EQN 1325
ECN 413/EQN 425
ROQ 425
(1) ECI119 can be procured from Heidenhain as either EnDat Sin/Cos or EnDat Digital.
LIC 4000
ECl 119
ROQ 437
ECN 1123/ EQN 1135
ECN 1325 / EQN 1337
ECI 1319/EQI 1331
ECI 1118/EQI 1130
ECN 125
Position initialization
Digital
Position tracking
Uses sine/cosine signals
Digital
Data frequency
100 kHz
4.125 MHz
Sine/cosine frequency
0…250 kHz
–
IMPORTANT
To properly support system EnDat feedback, the keying configuration in
drive Module Properties of the Logix Designer application must be selected
to use Kinetix 5700 drive firmware revision 5.0 or later.
IMPORTANT
Unprogrammed Smart feedback devices (Hiperface Sin/Cos, Hiperface DSL,
EnDat Sin/Cos, and EnDat Digital) are not supported. Unprogrammed as load
or feedback-only feedback types are supported. Contact your local
distributor or Rockwell Automation representative for support options.