38
Rockwell Automation Publication 2198-UM002E-EN-P - February 2018
Chapter 2
Plan the Kinetix 5700 Drive System Installation
Table 8 - Power Dissipation Specifications
Minimum Clearance Requirements
This section provides information to assist you in sizing your cabinet and
positioning your Kinetix 5700 drive system:
• Additional clearance is required for cables and wires or the shared-bus
connection system connected to the top of the drive modules.
– Capacitor modules require extra clearance above for wiring DC-bus
stud connections and installing the cover.
• Additional clearance is required if other devices are installed above and/
or below the drive module and have clearance requirements of their
own.
– Capacitor modules require extra clearance to route DC-bus wiring
into or away from the drive system.
• Additional clearance left and right of the drive module is required when
mounted adjacent to noise sensitive equipment or clean wire ways.
• The recommended minimum cabinet depth is 300 mm (11.81 in.).
DC-bus Power Supply Cat. No.
Usage as % of Rated Power Output
(watts)
20%
40%
60%
80%
100%
2198-P031
97
101
105
109
113
2198-P070
108
119
130
140
151
2198-P141
249
267
286
304
323
2198-P208
265
294
323
352
380
Dual-axis Inverter Cat. No.
2198-D006-ERS
x
17
29
41
53
65
2198-D012-ERS
x
34
58
82
106
130
2198-D020-ERS
x
52
84
116
148
180
2198-D032-ERS
x
100
155
210
265
320
2198-D057-ERS
x
252
354
456
558
660
Single-axis Inverter Cat. No.
2198-S086-ERS
x
190
255
325
400
475
2198-S130-ERS
x
225
340
460
590
725
2198-S160-ERS
x
270
420
570
760
950
iTRAK Power Supply Cat. No.
2198T-W25K-ER
206
272
338
404
470
Capacitor Module Cat. No.
2198-CAPMOD-2240
28
34
42
51
62
2198-CAPMOD-DCBUS-IO
1.1
1.4
1.6
2.1
2.5