20
Rockwell Automation Publication 2198-UM002E-EN-P - February 2018
Chapter 1
Start
8720MC-RPS Power Supply Configuration
In this example, three-phase AC input power is fed to the Bulletin 8720MC
regenerative power supply. The 8720MC-RPS DC-bus voltage supplies the
Kinetix 5700 DC-bus via the capacitor module. If the 8720MC-RPS190 is
used, the 2198-CAPMOD-DCBUS-IO extension module is required.
DC-bus full-regeneration is possible with this configuration.
Figure 3 - 8720MC-RPS Power Supply Installations
(1) This M1 contactor is controlled by the 8720MC regenerative power supply.
IMPORTANT
The 8720MC-RPS power supply is not compatible with the iTRAK power
supply.
1606-XL
Po we r S u p p l y
Input
Allen-Bradley
MOD
NET
MOD
NET
MOD
NET
1
I/O
6
5
10
2
1
2
1
2
1
1
I/O-A
6
5
10
1
I/O-B
6
5
10
1
I/O-A
6 1
I/O-B
6
5
10 5
10
UFB
UFB-A
UFB-B
UFB-A
UFB-B
D+
D-
D+
D-
D+
D-
MF-A
MF-B
MF-A
MF-B
D+
D-
MBRK
+
-
SB+/NC
S1A
SCA
S2A
SB-
NC
NC
NC
1
9
8
16
SB+/NC
S1A
SCA
S2A
SB-
S1B
SCB
S2B
SB+/NC
S1A
SCA
S2A
SB-
S1B
SCB
S2B
1
9
8
16
1
9
8
16
REGENERATIVE POWER SUPPLY
REGENERATIVE POWER SUPPLY
8720
8720
MC
MC
RST PRG ENT
READY
READY
FAULT
FAULT
PROGRAM
PROGRAM
kW
kW
V
A
MOD
NET
2
1
1
I/O-A
6 1
I/O-B
6
5
10 5
10
UFB-A
UFB-B
D+
D-
MF-B
D+
D-
1
9
8
16
SB+/NC
S1A
SCA
S2A
SB-
S1B
SCB
S2B
MOD
DC BUS
MODULE
STATUS
D+
D-
MF
1606-XL
xxx
24V DC Control, Digital Inputs,
and Motor Brake Power (customer-supplied)
AC Input Power
Kinetix 5700 Servo Drive System
(front view)
Kinetix 5700 Servo Drive System
(top view)
324…528V AC
Three-phase Input Power
Circuit
Protection
Magnetic
(1)
(M1) Contactor
Bonded Cabinet
Ground Bus
8720MC-RFI80
AC Line Filter
8720MC-LR
xx
Line Reactor
8720MC-RPS065-BM-HV2
Regenerative Power Supply
Single-axis
Inverter
Dual-axis Inverters
Capacitor
Module
8720MC-HF-B2
Harmonic Filter
8720MC-VA-B
Varistor
Bulletin 2198 shared-bus
connection system for DC-bus and
24V DC control power.
Shared DC-bus Power Input
Shared 24V Control Power Input
(24V shared-bus connection