130
Rockwell Automation Publication 2198-UM002E-EN-P - February 2018
Chapter 5
Connect the Kinetix 5700 Drive System
A mounting bracket is included with the 2198-H2DCK converter kit to secure
the kit to the drive. Install the mounting bracket in the bottom mounting
position on the kit, and the kit mounting holes on the drive.
Figure 85 - Wiring the 2198-H2DCK Feedback Converter Kit
Figure 86 - Wiring the 2198-K57CK-D15M Feedback Connector Kit
14
11
10
7
6
5
4
3
2
1
D+
D-
D+
D-
MF-A
MF-B
Shield Clamp
Clamp Screws (2)
Service Loops
Mounting Screws (2)
Mounting Bracket
The bottom mounting position
applies to all dual-axis and
single-axis inverters.
Refer to Hiperface to DSL Feedback Converter Kit Installation Instructions,
publication
, for converter kit specifications.
10-pin
Connector
Converter Kit Mounting Holes
(2198-D
xxx
-ERS
x
example is shown)
Tie Wrap for Stress Relief
and Wire Management
1. Place exposed cable shield
in the channel.
2. Place the shield clamp over
the exposed shield.
3. Tighten screws, torque
0.3 N•m (2.6 lb•in).
Exposed Shield
Aligned
in the Cable Channel
Pin 11
Pin 6
Pin 15
Pin 1
Pin 10
Pin 5
UFB
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
Shield Clamp
Mounting
Screws
2198-K57CK-D15M
Connector Kit
Bulletin 2090 Feedback Cable
Refer to Universal Feedback Connector Kit Installation Instructions, publication
, for connector kit specifications.
Clamp Screws (2)
Service
Loops
Tie Wrap is recommended
for Stress Relief and Wire
Management
1. Place exposed cable shield
in the channel.
2. Place the shield clamp over
the exposed shield.
3. Tighten screws, torque
0.34 N•m (3.0 lb•in).
Exposed Shield
Aligned
on the Ground Pad
16-pin
Connector