Rockwell Automation Publication 2198-UM002E-EN-P - February 2018
159
Configure and Start the Kinetix 5700 Drive System
Chapter 6
Table 88 - Safety Application Definitions
3.
From the Connection pull-down menu,
choose the Connection mode for your
motion application (see
for
definitions).
Table 89 - Module Connection Definitions
4.
From the Motion Safety
x
pull-down menu,
choose the integrated safety type (see
for definitions).
‘Motion Safety’ applies to 2198-S
xxx
-ERS4 (single-axis) inverters.
‘Motion Safety 1’ and ‘Motion Safety 2’ applies to 2198-D
xxx
-ERS4
(dual-axis) inverters.
Motion Safety and Motion Safety 1 align with Axis 1 configured in
Associated Axes. Motion Safety 2 aligns with Axis 3 configured in
Associated Axes.
Safety Application Mode
(1)
Safety Functions
Minimum Drive Module
(2)
Required
Drive Module Connection
Options
Minimum Controller Required
(3)
Hardwired
Hardwired STO
2198-
xxxx
-ERS3
Motion Only
• ControlLogix 5570
• CompactLogix 5370
Networked
Integrated STO
2198-
xxxx
-ERS3
• Motion and Safety
• Motion Only
• Safety Only
• GuardLogix 5570
• CompactLogix 5370
• Integrated STO
• Timed SS1
2198-
xxxx
-ERS3
• Motion and Safety
• Motion Only
• Safety Only
• GuardLogix 5570
• CompactLogix 5370
• Integrated STO
• Timed SS1
• Monitored SS1
• Controller-based safety functions
2198-
xxxx
-ERS4
• Motion and Safety
• Motion Only
• Safety Only
• GuardLogix 5580
• CompactLogix 5380
(1) For 2198-D
xxx
-ERS4 (dual-axis) inverters, you must configure axis 1 and 3 as Networked or Hardwired, they cannot be mixed.
(2) Where a 2198-
xxxx
-ERS3 drive is specified, a 2198-
xxxx
-ERS4 drive is backwards compatible, but not necessary for the specified safety application and function.
(3) Where a ControlLogix or CompactLogix (non-safety) controller is specified, a GuardLogix or Compact GuardLogix controller is backwards compatible, but not necessary for the specified safety
application, function, and connection. Also, GuardLogix 5580 and Compact GuardLogix 5380 controllers are backwards compatible with GuardLogix 5570 and Compact GuardLogix 5370 controllers.
TIP
When ‘Safety’ appears in the Connection mode, integrated safety is
implied.
Connection Mode
Safety Options
Description
Motion and Safety
Integrated mode
Motion connections and integrated STO are managed by this controller.
Motion Only
• Hardwired STO mode
• Integrated mode if there is a
secondary safety controller
• Motion connections are managed by this controller.
• Hardwired STO is controlled by the hardwired safety inputs or
Integrated is managed by another controller that has a Safety-only
connection to the drive.
Safety Only
Integrated mode
• Integrated STO is managed by this controller.
• Motion connections are managed by another controller that has a
Motion-only connection to the drive.