132
Rockwell Automation Publication 2198-UM002E-EN-P - February 2018
Chapter 5
Connect the Kinetix 5700 Drive System
Figure 88 - Extension Module Features and Indicators
Table 74 - Capacitor Module Connector Specifications
1
4
3
6
5
8
7
2
5700
2198-CAPMOD-DCBUS-IO
Extension Module
(side view, lug cover removed)
2198-CAPMOD-DCBUS-IO
Extension Module
(front view)
2198-CAPMOD-DCBUS-IO
Extension Module
(top views)
Item
Description
Item
Description
1
Ground lug
5
DC– M8 stud (external DC-bus)
2
Stud/lug cover with wires
(1)
6
DC+ M8 stud (external DC-bus), shown
with flexible bus-bar (2x)
3
Stud cover without wires
7
M8 hex nut
4
DC-bus (DC) connector
8
Lug spacer
(1) This example shows the lug cover oriented for wires exiting to the left (extension module is on the far left of drive configuration).
Rotate lug cover 180° when wires exit to the right (extension module is on the far right of drive configuration).
Connector
Description
Pin
Signal
Recommended
Wire Size
mm
2
(AWG)
Strip Length
mm (in.)
Torque Value
N•m (lb•in)
Module Status
MS-1
MS-2
RELAY+
RELAY-
0.14…1.5
(28…16)
7.0 (0.28)
0.22…0.25
(1.9…2.2)
PELV/SELV
24V power (plug)
CP-1
CP-2
24V+
24V-
0.5…2.5
(20…14)
7.0 (0.28)
0.22…0.25
(1.9…2.2)
DC-bus power
Bus-bar
DC-
DC+
N/A
(1)
(1)
DC bus connections are always made from one drive module to another over the shared-bus connection system. These terminals
do not receive discrete wires.
N/A
DC-bus studs
Bus-bar
N/A
N/A
18 (156)
Lugs
53.5 (1/0) 100 A
85.0 (3/0) 200 A
N/A
(2)
(2) Strip length for the DC-bus studs depend on the customer-supplied lugs.