Rockwell Automation Publication 2198-UM002E-EN-P - February 2018
81
Connector Data and Feature Descriptions
Chapter 4
Stegmann Hiperface Feedback
Figure 46 - Stegmann Hiperface Interface, MTR_SIN and MTR_COS Signals
Figure 47 - Stegmann Hiperface Interface, MTR_DATA Signals
56 pF
or
MTR_SIN- or
MTR_COS-
+
1 k
Ω
+
to AqB Counter
1 k
Ω
1 k
Ω
1 k
Ω
121
Ω
56 pF
220 pF
2 k
Ω
220 pF
to A/D Converter
2 k
Ω
+2.5V
+2.5V
-
-
Kinetix 5700
Servo Drive
+
to UART
from UART
from UART
100 pF
M
MTR_DATA-
1 k
Ω
to AqB Counter
1 k
Ω
1 k
Ω
100 pF
1 k
Ω
121
Ω
56 pF
56 pF
+5V
-
Shaded area indicates components that are part of the circuit, but support
other feedback device types (not used for Stegmann Hiperface support).
Kinetix 5700
Servo Drive