Mount the Kinetix 5700 Drive System
Chapter 3
Drill-hole Pattern Calculations
Follow these steps to calculate the left-to-right hole pattern for any
Kinetix 5700 drive module configuration by using
.
1.
The first hole location is zero.
2.
The second hole location is module width minus 55 mm.
3.
The next hole location is 55 mm.
4.
Repeat
for the remaining holes.
Figure 31 - Kinetix 5700 Mounting Hole Patterns
32.0 (1.26)
Module Top, reference
27.5 (1.08)
Dimensions are in mm (in.)
Module Top
176 (6.93)
Lower Mounting Hole
345 (13.58)
Lower Mounting Hole
420 (16.54)
Lower Mounting Hole
465 (18.31)
Lower Mounting Hole
Ø 6.0 (0.24)
Typical
Ø 6.0 (0.24) Typical
00.0 (0.00)
Upper Mounting Holes
45.0 (1.77) See Mounting Hole Pattern Calculations
30.0 (1.18) See Mounting Hole Pattern Calculations
100 mm
Wide Module
85 mm
Wide Module
55 mm
Wide Module
55 mm
Wide Module
Applies to only 2198-S160-ERS
x
Single-axis Inverter
Applies to 2198-P
xxx
Power Supplies,
2198-S086-ERS
x
and 2198-S130-ERS
x
Inverters,
and 2198-D
xxx
-ERS
x
Inverters
Applies to 2198-P
xxx
Power Supplies
2198-D
xxx
-ERS
x
Inverters, and
2198-CAPMOD-2240 Capacitor Module
First Mounting Hole
(typical) Upper and Lower
Mounting Hole
(all drive modules)
Applies to only
2198-CAPMOD-DCBUS-IN
Extension Module
45.0 (1.77) See Mounting Hole Pattern Calculations
100 mm
Wide Module
Applies to only 2198T-W25K-ER
iTRAK Power Supply