Fault Log
Fault text
.
FLT S20 - CONV OVERLOAD FL
Fault details
The problem as reported in
.
The converter thermal model indicates that the
temperature has exceeded the factory set capacity rating
of 110%.
Fault help
The Possible Solution as reported in
.
• Reduce the number of drives in the same bus group
• Reduce duty-cycle of commanded motion
Table 78 - Navigating the Inverter Menu (continued)
Menu/Sub Menu
Selections
Attributes
Description
Example Values
Menu/Sub Menu
Selections
Attributes
Description
Example Values
Module Info
Catalog number
2198-P
xxx
Firmware revision
FW REV: 1.1.450167
Hardware revision
HW REV: 1.1
Serial number
SERIAL#: xxxxxxxxxxx
Diagnostics>
Converter
Diagnostics
Bus diagnostics
BUS VOLT: 0.0V
BUS CUR: 0.0A
Converter diagnostics
CONV UTIL: 0.7%
CONV TEMP: 31.7C
Shunt utilization
SHUNT UTIL: 0.0%
Fault Log
Fault text
.
FLT S45 - FDBK COMM FL
Fault details
The problem as reported in
.
The number of consecutive missed or corrupted serial
data packets from the intelligent feedback device has
exceeded a factory set limit
Fault help
The Possible Solution as reported in
.
Check motor feedback cable and connector
Menu/Sub Menu
Selections
Attributes
Description
Example Values
Module Info
Catalog number
2198T-W25K-ER
Firmware revision
FW: 6.1.7100254
Hardware revision
HW REV: 1.1
Serial number
SERIAL#: xxxxxxxxxxx
Diagnostics>
Converter
Diagnostics
Bus diagnostics
BUS VOLT: 0.0V
Output 1 diagnostics
OUT1 VOLT: 0.0V
OUT1 AMPS: 0.0A
OUT1 PWR: 0.0kW
OUT1 UTIL: 0.0%
Output 2 diagnostics
OUT2 VOLT: 0.0V
OUT2 AMPS: 0.0A
OUT2 PWR: 0.0kW
OUT2 UTIL: 0.0%
Converter diagnostics
TOTAL PWR: 0.0kW
Fault Log
Fault text
.
FLT S38 - FUSE BLOWN
Fault details
The problem as reported in
.
The internal DC-bus power fuse is blown
Fault help
The Possible Solution as reported in
.
Return drive for repair if fault continues