Table 117 - Drive Behavior, FLT S
xx
Fault Codes
Exception Fault Code
Exception Text
Inverter
Modules
2198-
xxxx
Permanent
Magnet
Motor
Induction
Motor
Fault Action
Best Available
Stopping Action
(applies to major faults)
Ignore
Alar
m
Minor F
ault
M
ajor F
ault
FLT S02 – MTR COMMUTATION
Motor Commutation Fault
-ERS
x
X
X
Disable/Coast
FLT S03 – MTR OVERSPEED FL
Motor Overspeed Factory Limit Fault
-ERS
x
X
X
X
Disable/Coast
FLT S04 – MTR OVERSPEED UL
Motor Overspeed User Limit Fault
-ERS3
X
X
X
X
X
X
Decel/Hold
-ERS4
Ramped Decel
(5)
/Hold
FLT S05 – MTR OVERTEMP FL
Motor Overtemperature Factory Limit Fault
-ERS3
X
X
Disable/Coast
Motor Overtemperature Factory Limit Fault
(If #589 vertical load control)
-ERS4
X
Current Decel/Disable
Motor Overtemperature Factory Limit Fault
(If not #589 vertical load control)
Disable/Coast
FLT S07 – MTR OVERLOAD FL
Motor Thermal Overload Factory Limit Fault
-ERS3
X
X
X
Decel/Disable
-ERS4
Ramped Decel
/Disable
FLT S08 – MTR OVERLOAD UL
Motor Thermal OverLoad User Limit Fault
-ERS3
X
X
X
X
X
X
Decel/Hold
-ERS4
Ramped Decel
/Hold
FLT S09 – MTR PHASE LOSS
Motor Phase Loss
-ERS
x
X
X
X
X
X
Disable/Coast
FLT S10 – INV OVERCURRENT
Inverter Overcurrent Fault
-ERS
x
X
X
X
Disable/Coast
FLT S11 – INV OVERTEMP FL
Inverter Overtemperature Factory Limit Fault
-ERS3
X
X
X
Disable/Coast
Inverter Overtemperature Factory Limit Fault
(If #589 vertical load control)
-ERS4
Current Decel/Disable
Inverter Overtemperature Factory Limit Fault
(If not #589 vertical load control)
Disable/Coast
FLT S13 – INV OVERLOAD FL
Inverter Thermal Overload Factory Limit Fault
-ERS3
X
X
X
Disable/Coast
-ERS4
Current Decel/Disable
FLT S14 – INV OVERLOAD UL
Inverter Thermal Overload User Limit Fault
-ERS3
X
X
X
X
X
X
Decel/Hold
-ERS4
Ramped Decel
/Hold
FLT S16 – GROUND CURRENT
Ground Current Factory Limit Fault
-ERS
x
Single-axis
inverters
X
X
X
Disable/Coast
FLT S22 – AC POWER LOSS
Converter AC Power Loss Fault
-ERS3
X
X
X
X
X
X
Decel/Disable
-ERS4
Ramped Decel
/Disable
FLT S27 – BUS REG OVERTEMP FL
(1)
Bus Regulator Overtemperature Factory Limit
Fault
-ERS
x
X
X
X
Disable/Coast
FLT S32 – BUS CAPACITOR MODULE
FAILURE
Bus Capacitor Module Failure
-ERS3
X
X
X
X
X
X
Decel/Hold
-ERS4
Ramped Decel
/Hold
FLT S33 – BUS UNDERVOLT FL
Bus Undervoltage Factory Limit Fault
-ERS3
X
X
X
Decel/Disable
-ERS4
X
X
X
Ramped Decel
/Disable
FLT S34 – BUS UNDERVOLT UL
Bus Undervoltage User Limit Fault
-ERS3
X
X
X
X
X
X
Decel/Hold
-ERS4
Ramped Decel
/Hold
FLT S35 – BUS OVERVOLT FL
Bus Overvoltage Factory Limit Fault
-ERS
x
X
X
X
Disable/Coast
FLT S37 – BUS POWER LOSS
Bus Power Loss
-ERS3
X
X
X
X
X
X
Decel/Disable
-ERS4
Ramped Decel
/Disable
FLT S38 – FUSE BLOWN
Bus Power Fuse Blown Fault
-ERS
x
X
X
X
Disable/Coast