234
Rockwell Automation Publication 2198-UM002E-EN-P - February 2018
Chapter 7
Troubleshoot the Kinetix 5700 Drive System
NODE FLT Fault Codes
These NODE FLT fault codes apply to Kinetix 5700 DC-bus power supplies
and inverter modules.
Table 118 - Drive Behavior, FLT M
xx
Fault Codes
Exception Fault Code
Exception Text
Inverter
Modules
2198-
xxxx
Permanent
Magnet
Motor
Induction
Motor
Fault Action
Best Available
Stopping Action
(applies to major faults)
Ignor
e
Alarm
Mi
n
or F
aul
t
Major F
ault
FLT M02 – MOTOR VOLTAGE
(1)
Motor Voltage Mismatch Fault
-ERS
x
X
X
X
X
X
X
Disable/Coast
FLT M07 – FEEDBACK INCREMENTAL
COUNT ERROR FAULT
Feedback Incremental Count Error
Fault
-ERS
x
X
X
X
X
X
X
Disable/Coast
FLT M26 – RUNTIME ERROR
Runtime Error
-ERS
x
X
X
X
Disable/Coast
FLT M28 – SAFETY COMM
(2)
Safety Module Communication Error
-ERS
x
X
X
X
Disable/Coast
(1) Does not apply to induction motors in frequency control mode.
(2) Applies to drives in Integrated STO mode.
Table 119 - System Behavior, NODE FLT Fault Codes
Exception Fault Code
Exception Text
Inverter
Modules
2198-
xxxx
Permanent
Magnet Motor
Induction
Motor
Fault Action
Best Available
Stopping Action
(applies to major faults)
Ign
ore
Alarm
Min
or F
ault
Maj
or F
ault
NODE FLT 01 – LATE CTRL UPDATE
Control Connection Update Fault
-ERS3
X
X
X
Decel/Disable
-ERS4
Ramped Decel
(1)
/Disable
NODE FLT 02 – PROC WATCHDOG
Processor Watchdog Fault
-ERS
x
X
X
X
Disable/Coast
NODE FLT 03 – HARDWARE
Hardware Fault
-ERS
x
X
X
X
Disable/Coast
NODE FLT 05 – CLOCK SKEW FLT
Clock Skew Fault
-ERS3
X
X
X
Decel/Disable
-ERS4
Ramped Decel
/Disable
NODE FLT 06 – LOST CTRL CONN
Lost Controller Connection Fault
-ERS3
X
X
X
Decel/Disable
-ERS4
Ramped Decel
/Disable
NODE FLT 07 – CLOCK SYNC
Clock Sync Fault
-ERS3
X
X
X
Decel/Disable
-ERS4
Ramped Decel
/Disable
NODE FLT 09 – DUPLICATE IP ADDRESS
Duplicate IP Address Fault
-ERS
x
X
X
X
Disable/Coast
(1) Available only in Velocity Control mode. Available stopping action is Current Decel in Position Control mode.