Rockwell Automation Publication 2198-UM002E-EN-P - February 2018
97
Connect the Kinetix 5700 Drive System
Chapter 5
Remove/Install the Ground Screw/Jumper
We recommend that you remove or install the ground screw/jumper when the
drive module is removed from the panel and placed on its side on a solid work
surface.
To access or install the ground screw on DC-bus power supplies, dual-axis
inverters, and the iTRAK power supply, open the small plastic door on the
right side of the module.
Figure 60 - Remove/Install the Ground Screw
IMPORTANT
To determine if you need to remove or install the ground screw/jumper, see
ATTENTION:
When the ground screw/jumper is not installed the unit no
longer maintains line-to-neutral voltage protection, and the risk of
equipment damage exists.
Ground Screw
Access Door
DC-bus Power Supply
Dual-axis Inverter, or iTRAK Power Supply (side view)
(DC-bus power supply is shown)
Ground Screw
To determine if you need to remove or
install the ground screw, see
on
.
ATTENTION:
To avoid personal injury, the ground screw/jumper access door
must be kept closed when power is applied. If power was present and then
removed, wait at least 5 minutes for the DC-bus voltage to dissipate and
verify that no DC-bus voltage exists before accessing the ground screw/
jumper. This applies to the DC-bus power supply, dual-axis inverters, and
single-axis inverters.