Troubleshoot the Kinetix 5700 Drive System
Chapter 7
iTRAK Power Supply Behavior
The iTRAK power supply exceptions behavior, as defined in
shown in the following tables.
Table 111 - iTRAK Power Supply Exception Action Definitions
Exception Action
Definition
Hold
Continue regulating the iTRAK DC busses.
Disable
Actively discharge the iTRAK DC busses then disable the regulators.
Shutdown
Disable the regulators, iTRAK DC busses passively discharge.
Table 112 - iTRAK Power Supply Behavior, FLT S
xx
Fault Codes
Exception Fault Code
Exception Text
Module
Fault Action
Stopping Action
Ignore
Alarm
Minor F
ault
Ma
jor F
ault
FLT S18 - CONV OVERTEMP FL
Converter OverTemp Factory Limit Fault
iTRAK PS
X
Shutdown
FLT s20 - CONV OVERLOAD FL
Converter Thermal Overload Factory Limit Fault
iTRAK PS
X
Shutdown
FLT S25 - PRECHARGE FAILURE
Precharge Failure Fault
iTRAK PS
X
Shutdown
FLT S33 - BUS UNDERVOLT FL
Bus Undervoltage Factory Limit Fault
iTRAK PS
X
Shutdown
FLT S35 - BUS OVERVOLT FL
Bus Overvoltage Factory Limit Fault
iTRAK PS
X
Shutdown
FLT S38 - FUSE BLOWN
Bus Power Fuse Blown Fault
iTRAK PS
X
Shutdown
FLT S61 - ENABLE INPUT
Enable Input Deactivated
iTRAK PS
X
Disable
Table 113 - iTRAK Power Supply Behavior, FLT M
xx
Fault Codes
Exception Fault Code
Exception Text
Module
Fault Action
Stopping Action
Ignore
Ala
rm
Minor
F
ault
M
ajor F
ault
FLT M26 - RUNTIME ERROR
Runtime Error
iTRAK PS
X
Shutdown
Table 114 - iTRAK Power Supply Behavior, NODE FLT Fault Codes
Exception Fault Code
Exception Text
Module
Fault Action
Stopping Action
Ignor
e
Alarm
Mi
n
or F
aul
t
Major F
ault
NODE FLT 02 - PROC
Processor Watchdog Fault
iTRAK PS
X
Shutdown
NODE FLT 03 - HARDWARE
Hardware Fault
iTRAK PS
X
Shutdown
NODE FLT 09 - DUPLICATE IP ADDRESS
Duplicate IP address Fault
iTRAK PS
X
Shutdown