54
Rockwell Automation Publication 2198-UM002E-EN-P - February 2018
Chapter 3
Mount the Kinetix 5700 Drive System
Zero-stack Tab and Cutout
Engaging the zero-stack tab and cutout from one drive module to another
makes efficient use of panel space, especially for high axis-count installations.
Figure 28 - Zero-stack Tab and Cutout Example
For Kinetix 5700 system sizing examples, refer to Appendix C on
.
Shared-bus Connection
System
The shared-bus connection system is used to extend the DC-bus power and
24V control power from one drive module to another.
DC-bus Connection System
The DC-bus connection system is required and comprised of these two
components:
• DC-bus links that are inserted between drive modules to extend the
DC-bus from one drive module to another.
• DC-bus end-caps that are inserted into the first and last drive modules
to cover the exposed DC-bus connector on both ends of the bus.
IMPORTANT
Engaging the zero-stack tab and cutout from module-to-module is
required for any input power configuration. This is done to make sure that
the DC-bus connectors are spaced properly to accept the shared-bus
connection system.
MOD
NET
MOD
NET
Kinetix 5700 Drive Modules
(front view)
Zero-stack Tab
and Cutout Engaged
IMPORTANT
The zero-stack tab and cutout must be engaged between adjacent drive
modules for the shared-bus connection system to fit properly.