ipLDK-60
Issue 2.0
Admin Programming Manual
July, 2010
64
3.3.3
CO Line Attributes II (PGM 142)
PGM 142 is one of three PGMs to assign general attributes to the CO line range. Also, see PGMs 141 and 146.
Procedure:
1. Press
the
[TRANS/PGM]
button.
2. Dial
142.
3. Enter the appropriate CO line Range.
4. Select the desired Flexible button.
5. Enter the appropriate value.
6. Press
the
[Hold/Save]
button.
PGM
142
Flex
Btn
Description
Default
Values
CO Line Name
Display
1
When enabled (On), the assigned CO Line Name, Flexible button 2, displays in the
DKT LCD for incoming calls on the CO line.
0 (Off)
0 = Off
1 = On
CO Line Name
Assign
2
This parameter assigns the name for the CO line. The name can be up to 12
characters. Refer to the Dial Pad Character chart below for dial pad entries.
No assignment
12 characters
Metering Unit
3
This parameter defines the type of Metering Signal the system expects to receive
from the PSTN.
00 (None)
00 = None
01 = 50 Hz
02 = 12 KHz
03 = 16 KHz
04 = Singular Polarity
Reverse (SPR)
05 = Plural Polarity
Reverse (PPR)
06 = No Polarity
Summary of Contents for ipldk-60
Page 1: ...Feature Description Operation Manual ...
Page 268: ......
Page 269: ...Admin Programming Manual ...
Page 388: ...ipLDK 60 Issue 2 0 Admin Programming Manual July 2010 113 Blank 1 2 3 ...
Page 512: ......