![LG-Ericsson ipldk-60 Feature Description And Operation Manual Download Page 384](http://html1.mh-extra.com/html/lg-ericsson/ipldk-60/ipldk-60_feature-description-and-operation-manual_1906054384.webp)
ipLDK-60
Issue 2.0
Admin Programming Manual
July, 2010
109
3.5.17 Pulse Dial Ratio (PGM 176)
PGM 176 establishes the analog CO line out-pulse dial close to open ratio, 60/40 or 67/33.
Procedure:
1. Press
the
[TRANS/PGM]
button.
2. Dial
176.
3. Select the desired Flexible button.
4. Enter the appropriate value.
5. Press
the
[Hold/Save]
button.
PGM
176
Flex
Btn
Description
Default
Values
Pulse dial ratio
This parameter defines the close/open ratio for dial pulses on an analog CO line.
1 (67/33)
0 =60/40
1 = 67/33
Summary of Contents for ipldk-60
Page 1: ...Feature Description Operation Manual ...
Page 268: ......
Page 269: ...Admin Programming Manual ...
Page 388: ...ipLDK 60 Issue 2 0 Admin Programming Manual July 2010 113 Blank 1 2 3 ...
Page 512: ......