ipLDK-60
Issue 2.0
Admin Programming Manual
July, 2010
78
PGM
152
Flex
Btn
Description
Default
Values
Out-pulse Rate
6
not used
Seize Timer
7
This parameter defines the duration of the seizure signal provided by the T1 CO line
for DID and TIE lines.
3 (60 milli-
seconds)
000 ~ 127 in 20-milli-
second increments
Release Timer
8
This parameter defines the duration of the release signal provided by the T1 CO line
for DID and TIE lines.
7 (140 milli-
seconds)
000 ~ 127 in 20-milli-
second increments
IASG Mode
9
not used
1 (DTMF)
0 = Pulse
1 = DTMF
Ring Detect Time
10
This parameter defines the minimum incoming Ring-on signal to be considered a
valid ring signal for Loop/Ground Start T1 CO lines. Shorter ring-on periods are
ignored.
2 (200 milli-
seconds
2 ~ 9 in 100-milli-
second increments
Ring Stop Time
11
This parameter defines the maximum duration of the Ring-off period to be
considered a valid ring signal for Loop/Ground Start T1 CO lines. Longer Ring-off
signals are considered an abandoned call.
60 (6 seconds)
10 ~ 60 in 100-milli-
second increments
Collect Digit
Timer
12 not
used
Store Timer
13
not used
Summary of Contents for ipldk-60