3.3.8
CO Line Caller Id (CID) Attributes (PGM 147)
PGM 147 defines the Caller Id characteristics associated with analog CO lines.
Procedure:
1. Press
the
[TRANS/PGM]
button.
2. Dial
147.
3. Enter the appropriate CO Line Range.
4. Press the desired Flexible button.
5. Enter the appropriate value.
6. Press
the
[Hold/Save]
button.
PGM
147
Flex
Btn
Description
Default
Values
CID Mode Select
1
This parameter defines the type of Caller Id signal provided by the PSTN.
1 (FSK)
0 = Disable
1 = FSK
2 = DTMF
3 = Russia CID
4 = Russia Auto CID
CID Name
Display
2
When the analog CO line provides the caller’s name as well as number, the system
can display the telephone number or the name and the telephone number received.
0 (Telephone
number)
0 = Tel. number.
1 = Name
RCID Detect
3
This parameter determines the types of call that include CID, only local calls, or all
calls. (Intended for use in Russia only)
0 (Local)
0 = Local
1 = All
RCID Request
4
This parameter determines if the system will request Caller ID from the network.
(Intended for use in Russia only)
1 (Auto)
0 = Auto
1 = User
RCID Request
Timer
5
When RCID Request (Flexible button 4) is set to auto, the system will delay sending
the request for the setting of this timer. (Intended for use in Russia only)
150 (1.5
seconds)
010 ~ 150 in 10 milli-
second increments