![LG-Ericsson ipldk-60 Feature Description And Operation Manual Download Page 351](http://html1.mh-extra.com/html/lg-ericsson/ipldk-60/ipldk-60_feature-description-and-operation-manual_1906054351.webp)
ipLDK-60
Issue 2.0
Admin Programming Manual
July, 2010
76
PGM
147
Flex
Btn
Description
Default
Values
RCID Virtual
Answer Timer
6
When RCID Request (Flexible button 4) is set to Auto, the system automatically
answers incoming calls and routes them the appropriate Station(s). If the call is not
answered in the Virtual Answer time, the call is disconnected form the system.
(Intended for use in Russia only)
020 (20 seconds)
001 ~ 300 in 1
second increments
RCID Digit
Number
7
This parameter defines the number of digits of the received CID to display.
(Intended for use in Russia only)
07
04 ~ 10
RCID Request
Count
8
This parameter determines the number of times the system will request CID from the
network when RCID Request is set to Auto. The maximum value is 3. (Intended for
use in Russia only)
1
1 ~ 3
RCID Request
Delay
9
This parameter determines the time the system will wait between RCID Requests.
(Intended for use in Russia only)
10 (100 milli-
seconds)
10 ~ 30 in 10 milli-
second increments
Summary of Contents for ipldk-60
Page 1: ...Feature Description Operation Manual ...
Page 268: ......
Page 269: ...Admin Programming Manual ...
Page 388: ...ipLDK 60 Issue 2 0 Admin Programming Manual July 2010 113 Blank 1 2 3 ...
Page 512: ......