ipLDK-60
Issue 2.0
Admin Programming Manual
July, 2010
116
3.5.21 System Timers (PGM 180-184)
3.5.21.1 System Timers I (PGM 180)
PGM 180 is one of three PGMs used to define timers that affect system wide operations. See also PGM 181 and 182.
Procedure:
1. Press
the
[TRANS PGM]
button.
2. Dial
180.
3. Select the desired Flexible button.
4. Enter the appropriate value.
5. Press
the
[Hold/Save]
button.
PGM
180
Flex
Btn
Description
Default
Values
Attendant Recall
Timer
1
This parameter sets the duration a call recalls to the Attendant before it is
disconnected. Calls can recall from Hold, Transfer, etc.
01 minutes
00 ~ 60 in 1 minute
increments
Call Park Recall
Timer
2
This parameter sets the duration a call will remain parked before recalling the station
that parked the call.
120 seconds
00 ~ 600 in 1 second
increments
Camp On Recall
Timer
3
This parameter sets the duration a transferred call will remain camped on to a station
before recalling the transferring station.
030 seconds
000 ~ 200 in 1
second increments
Exclusive Hold
Recall Timer
4
This parameter sets the duration a call will remain on Exclusive hold before recalling
the station that placed the call on hold.
060 seconds
000 ~ 300 in 1
second increments
I-Hold Recall
Timer
5
This parameter sets the duration the station will receive recall before the Attendant
will also receive the recall.
030 seconds
000 ~ 300 in 1
second increments
Sys Hold Recall
Timer
6
This parameter sets the duration a call will remain on System hold before recalling
the station that placed the call on hold.
030 seconds
000 ~ 300 in 1
second increments
Summary of Contents for ipldk-60
Page 1: ...Feature Description Operation Manual ...
Page 268: ......
Page 269: ...Admin Programming Manual ...
Page 388: ...ipLDK 60 Issue 2 0 Admin Programming Manual July 2010 113 Blank 1 2 3 ...
Page 512: ......