host1(config-subif-atm-vc)#
exit
host1(config-subif)#
The following commands, which are available only in ATM VC Configuration mode,
configure nondefault VC integrity and alarm surveillance parameters on a data PVC.
In this example, the VC integrity parameters configured with the
oam retry
command
include the up retry count (4), down retry count (6), and retry frequency (2). The
alarm surveillance parameters configured with the
oam ais-rdi
command include
the alarm down count (2) and alarm clear timeout duration (4 seconds). Issuing the
exit
command causes the configuration to take effect.
host1(config)#
interface atm 3/0.0
host1(config-subif)#
pvc 32 0/32
host1(config-subif-atm-vc)#
oam retry 4 6 2
host1(config-subif-atm-vc)#
oam ais-rdi 2 4
host1(config-subif-atm-vc)#
exit
host1(config-subif)#
oam ais-rdi
■
Use to configure surveillance parameters for AIS and RDI F5 OAM fault
management cells on an ATM data PVC.
■
You can optionally specify the following values:
■
alarmDownCount
—Number of successive alarm cells, in the range 1–60, for
the router to receive before reporting that a PVC is down; the default value
is 1
■
alarmClearTimeout
—Number of seconds, in the range 3–60, for the router
to wait before reporting that a PVC is up after the PVC has stopped receiving
alarm cells; the default value is 3
■
To configure these alarm surveillance parameters, you must use the
oam ais-rdi
command in ATM VC Configuration mode. There is no equivalent
atm pvc
command to configure these parameters.
■
You must issue the
exit
command from ATM VC Configuration mode for the
configuration to take effect.
■
Example
host1(config-subif-atm-vc)#
oam ais-rdi 5 10
host1(config-subif-atm-vc)#
exit
■
Use the
no
version to restore the default values for the alarm down count and
alarm clear timeout duration.
■
See oam ais-rdi.
oam cc
■
Use to enable F5 OAM CC verification on an ATM data PVC.
■
You can optionally specify one of the following values to configure CC cell flows:
■
segment
—Opens an F5 OAM CC segment cell flow
■
end-to-end
—Opens an F5 OAM CC end-to-end cell flow
52
■
Configuring Individual ATM PVC Parameters
JUNOSe 11.1.x Link Layer Configuration Guide
Summary of Contents for JUNOSE 11.1.X - LINK LAYER CONFIGURATION 4-7-2010
Page 6: ...vi...
Page 8: ...viii JUNOSe 11 1 x Link Layer Configuration Guide...
Page 26: ...xxvi List of Figures JUNOSe 11 1 x Link Layer Configuration Guide...
Page 34: ...2 Chapters JUNOSe 11 1 x Link Layer Configuration Guide...
Page 230: ...198 Monitoring VLAN and S VLAN Subinterfaces JUNOSe 11 1 x Link Layer Configuration Guide...
Page 258: ...226 Monitoring 802 3ad Link Aggregation JUNOSe 11 1 x Link Layer Configuration Guide...
Page 334: ...302 Troubleshooting JUNOSe 11 1 x Link Layer Configuration Guide...
Page 394: ...362 Monitoring Multiclass MLPPP JUNOSe 11 1 x Link Layer Configuration Guide...
Page 406: ...374 Monitoring POS JUNOSe 11 1 x Link Layer Configuration Guide...
Page 468: ...436 Troubleshooting JUNOSe 11 1 x Link Layer Configuration Guide...
Page 498: ...466 Monitoring Bridged Ethernet JUNOSe 11 1 x Link Layer Configuration Guide...
Page 546: ...514 Monitoring Cisco HDLC JUNOSe 11 1 x Link Layer Configuration Guide...
Page 747: ...Part 2 Index Index on page 717 Index 715...
Page 748: ...716 Index JUNOSe 11 1 x Link Layer Configuration Guide...
Page 774: ...742 Index JUNOSe 11 1 x Link Layer Configuration Guide...