COPIER (Service mode for copier) > OPTION (Specification setting mode) > USER
SMD-EXPT
1
ON/OFF remote UI service mode data dspl
Detail
To set whether to display "service mode data" as the target data of export on remote UI.
When 1 is set, the same service mode data can be registered in the case of installing more than
a machine at the same time.
Use Case
When installing more than a machine at the same time
Adj/Set/Operate Method
1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/Adj/Set Range
0 to 1
0: OFF, 1: ON
Default Value
0
SNDSTREN
1
Set of setting delete aftr scan and send
Detail
To set whether to delete the transmission setting/address after transmission on the "Scan and
Send" screen.
Use Case
Upon user's request
Adj/Set/Operate Method
1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/Adj/Set Range
0 to 2
0: Deleted, 1: Retained only the transmission setting, 2: Retained the transmission setting and
address
Default Value
JP:1, USA:0, EUR:0, AU:0, CN:0, KR:0, TW:0, ASIA:0
FAXSTREN
1
Set of setting delete aftr fax transmit
Detail
To set whether to delete the transmission settings except for the address after transmission from
the "Fax" screen.
Use Case
Upon user's request
Adj/Set/Operate Method
1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/Adj/Set Range
0 to 1
0: Deleted, 1: Retained
Default Value
JP:1, USA:0, EUR:0, AU:0, CN:0, KR:0, TW:0, ASIA:0
SJ-UNMSK
2
ON/OFF secured job masking cancellation
Detail
To set whether to mask other people's secured jobs.
When 0 is set, operation of other people's secured jobs is not possible because they are masked.
When COIN is set to 6 or 7 (charge mode: Type-C), set 1. Masking is canceled and other people's
secured jobs can be operated.
It is enabled at MEAP authentication.
Use Case
When operating secured jobs in charge mode Type-C
Adj/Set/Operate Method
1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/Adj/Set Range
0 to 1
0: OFF (Masking enabled), 1: ON (Masking canceled)
Default Value
0
Related Service Mode
COPIER> OPTION> ACC> COIN
8. Service Mode
923
Summary of Contents for imageRUNNER ADVANCE C3330 Series
Page 1: ...Revision 7 0 imageRUNNER ADVANCE C3330 C3325 C3320 Series Service Manual ...
Page 18: ...Product Overview 1 Product Lineup 7 Features 11 Specifications 17 Parts Name 26 ...
Page 518: ...Error Jam Alarm 7 Overview 507 Error Code 511 Jam Code 617 Alarm Code 624 ...
Page 1020: ...9 Installation 1008 ...
Page 1022: ...2 Perform steps 3 to 5 in each cassette 9 Installation 1010 ...
Page 1024: ...5 6 Checking the Contents Cassette Feeding Unit 1x 3x 2x 1x 9 Installation 1012 ...
Page 1027: ...3 4 NOTE The removed cover will be used in step 6 5 2x 2x 9 Installation 1015 ...
Page 1046: ...When the Kit Is Not Used 1 2 Close the Cassette 2 When the Kit Is Used 1 9 Installation 1034 ...
Page 1068: ... Removing the Covers 1 2x 2 1x 9 Installation 1056 ...
Page 1070: ...3 1x 1x 9 Installation 1058 ...
Page 1083: ...6 7 TP M4x8 2x 2x 9 Installation 1071 ...
Page 1084: ...When Installing the USB Keyboard 1 Cap Cover Wire Saddle 9 Installation 1072 ...
Page 1129: ...9 2x 10 2x 11 9 Installation 1117 ...
Page 1135: ...Remove the covers 1 ws 2x 2 1x 9 Installation 1123 ...
Page 1140: ...2 2x 3 Connect the power plug to the outlet 4 Turn ON the power switch 9 Installation 1128 ...
Page 1176: ... A 2x Installing the Covers 1 1x 2 2x 9 Installation 1164 ...
Page 1190: ...14 Install the Cable Guide to the HDD Frame 4 Hooks 1 Boss 9 Installation 1178 ...