COPIER (Service mode for copier) > OPTION (Specification setting mode) > IMG-FIX
TMP-TB20
1
Set fixing control temp: extra-long pln
Detail
To set the offset of fixing control temperature for extra-long plain paper 1/2/3, recycled paper 1/2/3,
thin paper, colored paper, tracing paper, pre-punched paper and bond paper (width: 300 to 320
mm).
As the value is changed by 1, the control temperature is changed by 5 deg C.
Increase the value when a fixing failure occurs, and decrease the value when fixing offset occurs.
Use Case
When a fixing failure/fixing offset occurs on extra-long plain paper 1/2/3, recycled paper 1/2/3, thin
paper, colored paper, tracing paper, pre-punched paper and bond paper
Adj/Set/Operate Method
Enter the setting value (switch negative/positive by -/+ key) and press OK key.
Caution
If the value is too large, fixing offset may occur.
If the value is too small, a fixing failure may occur.
Display/Adj/Set Range
-2 to 2
-2: -10 deg C, -1: -5 deg C, 0: 0 deg C, 1: +5 deg C, 2: +10 deg C
Unit
deg C
Default Value
0
Amount of Change per
Unit
5
TMP-TB21
1
Set fixing control temp:extra-long hvy 1
Detail
To set the offset of fixing control temperature for extra-long heavy paper 1/2/3/4, coated paper
1/2/3 and label (width: 300 to 305 mm).
As the value is changed by 1, the control temperature is changed by 5 deg C.
Increase the value when a fixing failure occurs, and decrease the value when fixing offset occurs.
Use Case
When a fixing failure/fixing offset occurs on extra-long heavy paper 1/2/3/4, coated paper 1/2/3
and label
Adj/Set/Operate Method
Enter the setting value (switch negative/positive by -/+ key) and press OK key.
Caution
If the value is too large, fixing offset may occur.
If the value is too small, a fixing failure may occur.
Display/Adj/Set Range
-2 to 2
-2: -10 deg C, -1: -5 deg C, 0: 0 deg C, 1: +5 deg C, 2: +10 deg C
Unit
deg C
Default Value
0
Related Service Mode
COPIER> OPTION> IMG-FIX> TMP-TB22
Amount of Change per
Unit
5
TMP-TB22
1
Set fixing control temp:extra-long hvy 2
Detail
To set the offset of fixing control temperature for extra-long heavy paper 1/2/3/4, coated paper
1/2/3 and label (width: 305.1 to 320 mm).
As the value is changed by 1, the control temperature is changed by 5 deg C.
Increase the value when a fixing failure occurs, and decrease the value when fixing offset occurs.
Use Case
When a fixing failure/fixing offset occurs on extra-long heavy paper 1/2/3/4, coated paper 1/2/3
and label
Adj/Set/Operate Method
Enter the setting value (switch negative/positive by -/+ key) and press OK key.
Caution
If the value is too large, fixing offset may occur.
If the value is too small, a fixing failure may occur.
Display/Adj/Set Range
-2 to 2
-2: -10 deg C, -1: -5 deg C, 0: 0 deg C, 1: +5 deg C, 2: +10 deg C
Unit
deg C
Default Value
0
Related Service Mode
COPIER> OPTION> IMG-FIX> TMP-TB21
Amount of Change per
Unit
5
8. Service Mode
900
Summary of Contents for imageRUNNER ADVANCE C3330 Series
Page 1: ...Revision 7 0 imageRUNNER ADVANCE C3330 C3325 C3320 Series Service Manual ...
Page 18: ...Product Overview 1 Product Lineup 7 Features 11 Specifications 17 Parts Name 26 ...
Page 518: ...Error Jam Alarm 7 Overview 507 Error Code 511 Jam Code 617 Alarm Code 624 ...
Page 1020: ...9 Installation 1008 ...
Page 1022: ...2 Perform steps 3 to 5 in each cassette 9 Installation 1010 ...
Page 1024: ...5 6 Checking the Contents Cassette Feeding Unit 1x 3x 2x 1x 9 Installation 1012 ...
Page 1027: ...3 4 NOTE The removed cover will be used in step 6 5 2x 2x 9 Installation 1015 ...
Page 1046: ...When the Kit Is Not Used 1 2 Close the Cassette 2 When the Kit Is Used 1 9 Installation 1034 ...
Page 1068: ... Removing the Covers 1 2x 2 1x 9 Installation 1056 ...
Page 1070: ...3 1x 1x 9 Installation 1058 ...
Page 1083: ...6 7 TP M4x8 2x 2x 9 Installation 1071 ...
Page 1084: ...When Installing the USB Keyboard 1 Cap Cover Wire Saddle 9 Installation 1072 ...
Page 1129: ...9 2x 10 2x 11 9 Installation 1117 ...
Page 1135: ...Remove the covers 1 ws 2x 2 1x 9 Installation 1123 ...
Page 1140: ...2 2x 3 Connect the power plug to the outlet 4 Turn ON the power switch 9 Installation 1128 ...
Page 1176: ... A 2x Installing the Covers 1 1x 2 2x 9 Installation 1164 ...
Page 1190: ...14 Install the Cable Guide to the HDD Frame 4 Hooks 1 Boss 9 Installation 1178 ...