![Canon imageRUNNER ADVANCE C3330 Series Service Manual Download Page 753](http://html1.mh-extra.com/html/canon/imagerunner-advance-c3330-series/imagerunner-advance-c3330-series_service-manual_4223874753.webp)
COPIER (Service mode for copier) > ADJUST (Adjustment mode) > DENS
CONT-Y
1
ATR Sensor (Y) control voltage entry
Detail
To enter the density detection control voltage of the ATR Sensor (Y).
When replacing the DC Controller PCB/clearing RAM data, enter the value of service label.
Use Case
When checking the value before replacement of the DC Controller PCB/clearing of RAM data and
then re-entering the value after clearing of the data
Adj/Set/Operate Method
Enter the setting value, and then press OK key.
Caution
The value changes if the Developing Unit is initialized (INISET-Y/4).
Display/Adj/Set Range
0 to 255
Default Value
123 (It may vary by initialization of the Developing Unit when clearing RAM data.)
Related Service Mode
COPIER> FUNCTION> INSTALL> INISET-Y/4
CONT-M
1
ATR Sensor (M) control voltage entry
Detail
To enter the density detection control voltage of the ATR Sensor (M).
When replacing the DC Controller PCB/clearing RAM data, enter the value of service label.
Use Case
When checking the value before replacement of the DC Controller PCB/clearing of RAM data and
then re-entering the value after clearing of the data
Adj/Set/Operate Method
Enter the setting value, and then press OK key.
Caution
The value changes if the Developing Unit is initialized (INISET-M/4).
Display/Adj/Set Range
0 to 255
Default Value
122 (It may vary by initialization of the Developing Unit when clearing RAM data.)
Related Service Mode
COPIER> FUNCTION> INSTALL> INISET-M/4
CONT-C
1
ATR Sensor (C) control voltage entry
Detail
To enter the density detection control voltage of the ATR Sensor (C).
When replacing the DC Controller PCB/clearing RAM data, enter the value of service label.
Use Case
When checking the value before replacement of the DC Controller PCB/clearing of RAM data and
then re-entering the value after clearing of the data
Adj/Set/Operate Method
Enter the setting value, and then press OK key.
Caution
The value changes if the Developing Unit is initialized (INISET-C/4).
Display/Adj/Set Range
0 to 255
Default Value
121 (It may vary by initialization of the Developing Unit when clearing RAM data.)
Related Service Mode
COPIER> FUNCTION> INSTALL> INISET-C/4
CONT-K
1
ATR Sensor (Bk) control voltage entry
Detail
To enter the density detection control voltage of the ATR Sensor (Bk).
When replacing the DC Controller PCB/clearing RAM data, enter the value of service label.
Use Case
When checking the value before replacement of the DC Controller PCB/clearing of RAM data and
then re-entering the value after clearing of the data
Adj/Set/Operate Method
Enter the setting value, and then press OK key.
Caution
The value changes if the Developing Unit is initialized (INISET-K/4).
Display/Adj/Set Range
0 to 255
Default Value
120 (It may vary by initialization of the Developing Unit when clearing RAM data.)
Related Service Mode
COPIER> FUNCTION> INSTALL> INISET-K/4
8. Service Mode
741
Summary of Contents for imageRUNNER ADVANCE C3330 Series
Page 1: ...Revision 7 0 imageRUNNER ADVANCE C3330 C3325 C3320 Series Service Manual ...
Page 18: ...Product Overview 1 Product Lineup 7 Features 11 Specifications 17 Parts Name 26 ...
Page 518: ...Error Jam Alarm 7 Overview 507 Error Code 511 Jam Code 617 Alarm Code 624 ...
Page 1020: ...9 Installation 1008 ...
Page 1022: ...2 Perform steps 3 to 5 in each cassette 9 Installation 1010 ...
Page 1024: ...5 6 Checking the Contents Cassette Feeding Unit 1x 3x 2x 1x 9 Installation 1012 ...
Page 1027: ...3 4 NOTE The removed cover will be used in step 6 5 2x 2x 9 Installation 1015 ...
Page 1046: ...When the Kit Is Not Used 1 2 Close the Cassette 2 When the Kit Is Used 1 9 Installation 1034 ...
Page 1068: ... Removing the Covers 1 2x 2 1x 9 Installation 1056 ...
Page 1070: ...3 1x 1x 9 Installation 1058 ...
Page 1083: ...6 7 TP M4x8 2x 2x 9 Installation 1071 ...
Page 1084: ...When Installing the USB Keyboard 1 Cap Cover Wire Saddle 9 Installation 1072 ...
Page 1129: ...9 2x 10 2x 11 9 Installation 1117 ...
Page 1135: ...Remove the covers 1 ws 2x 2 1x 9 Installation 1123 ...
Page 1140: ...2 2x 3 Connect the power plug to the outlet 4 Turn ON the power switch 9 Installation 1128 ...
Page 1176: ... A 2x Installing the Covers 1 1x 2 2x 9 Installation 1164 ...
Page 1190: ...14 Install the Cable Guide to the HDD Frame 4 Hooks 1 Boss 9 Installation 1178 ...