![Canon imageRUNNER ADVANCE C3330 Series Service Manual Download Page 834](http://html1.mh-extra.com/html/canon/imagerunner-advance-c3330-series/imagerunner-advance-c3330-series_service-manual_4223874834.webp)
COPIER (Service mode for copier) > FUNCTION (Operation / inspection mode) > PART-CHK
SL
1
Specification of operation solenoid
Detail
To specify the solenoid to operate.
Use Case
When replacing the solenoid/checking the operation
Adj/Set/Operate Method
Enter the value, and then press OK key.
Display/Adj/Set Range
1 to 2
1: Registration Shutter Solenoid (SL02)
2: Duplex Reverse Solenoid (SL06)
Default Value
1
Related Service Mode
COPIER> FUNCTION> PART-CHK> SL-ON
SL-ON
1
Operation check of solenoid
Detail
To start operation check of the solenoid specified by SL.
The operation stops after "ON for 2 sec" => "OFF for 5 sec" => "ON for 2 sec" => "OFF for 5 sec"
=> "ON for 2 sec".
Use Case
When replacing the solenoid/checking the operation
Adj/Set/Operate Method
Select the item, and then press OK key.
Display/Adj/Set Range
During operation: ACTIVE, When operation finished normally: OK!
Required Time
1 min
Related Service Mode
COPIER> FUNCTION> PART-CHK> SL
■ CLEAR
COPIER (Service mode for copier) > FUNCTION (Operation / inspection mode) > CLEAR
ERR
1
Clearing of error code
Detail
To clear error codes (E001, E002 and E003).
Use Case
At error occurrence
Adj/Set/Operate Method
1) Select the item, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/Adj/Set Range
During operation: ACTIVE, When operation finished normally: OK!
DC-CON
1
Clearing of DC Controller PCB RAM data
Detail
To clear the RAM data of the DC Controller PCB.
Use Case
When clearing RAM data of the DC Controller PCB
Adj/Set/Operate Method
1) Select the item, and then press OK key.
2) Turn OFF/ON the main power switch.
Caution
- Output the service mode setting values by P-PRINT before execution. After execution, enter
necessary setting value.
- The RAM data is cleared after the main power switch is turned OFF/ON.
Related Service Mode
COPIER> FUNCTION> MISC-P> P-PRINT
R-CON
1
RAM clear of Reader Unit
Detail
To clear the RAM data of the Reader Unit.
Use Case
When clearing the RAM data of the Reader Unit
Adj/Set/Operate Method
1) Select the item, and then press OK key.
2) Turn OFF/ON the main power switch.
Caution
- Before execution of this item, be sure to output the service mode setting values by P-PRINT.
After execution, enter necessary setting values.
- The RAM data is cleared after the main power switch is turned OFF/ON.
Related Service Mode
COPIER> FUNCTION> MISC-P> P-PRINT
8. Service Mode
822
Summary of Contents for imageRUNNER ADVANCE C3330 Series
Page 1: ...Revision 7 0 imageRUNNER ADVANCE C3330 C3325 C3320 Series Service Manual ...
Page 18: ...Product Overview 1 Product Lineup 7 Features 11 Specifications 17 Parts Name 26 ...
Page 518: ...Error Jam Alarm 7 Overview 507 Error Code 511 Jam Code 617 Alarm Code 624 ...
Page 1020: ...9 Installation 1008 ...
Page 1022: ...2 Perform steps 3 to 5 in each cassette 9 Installation 1010 ...
Page 1024: ...5 6 Checking the Contents Cassette Feeding Unit 1x 3x 2x 1x 9 Installation 1012 ...
Page 1027: ...3 4 NOTE The removed cover will be used in step 6 5 2x 2x 9 Installation 1015 ...
Page 1046: ...When the Kit Is Not Used 1 2 Close the Cassette 2 When the Kit Is Used 1 9 Installation 1034 ...
Page 1068: ... Removing the Covers 1 2x 2 1x 9 Installation 1056 ...
Page 1070: ...3 1x 1x 9 Installation 1058 ...
Page 1083: ...6 7 TP M4x8 2x 2x 9 Installation 1071 ...
Page 1084: ...When Installing the USB Keyboard 1 Cap Cover Wire Saddle 9 Installation 1072 ...
Page 1129: ...9 2x 10 2x 11 9 Installation 1117 ...
Page 1135: ...Remove the covers 1 ws 2x 2 1x 9 Installation 1123 ...
Page 1140: ...2 2x 3 Connect the power plug to the outlet 4 Turn ON the power switch 9 Installation 1128 ...
Page 1176: ... A 2x Installing the Covers 1 1x 2 2x 9 Installation 1164 ...
Page 1190: ...14 Install the Cable Guide to the HDD Frame 4 Hooks 1 Boss 9 Installation 1178 ...